Occupational allergy after exposure to caddis flies at a hydroelectric power plant.

نویسندگان

  • A Kraut
  • J Sloan
  • F Silviu-Dan
  • Z Peng
  • D Gagnon
  • R Warrington
چکیده

A cross sectional survey was conducted in a hydroelectric power plant in which the workforce was exposed to large numbers of caddis flies. 28 of 57 employees participated. About 50% of the participants reported work related eye, nose, and sinus symptoms and wheezing. Working in locations with greater exposure to caddis flies was significantly associated with work related symptoms. 17 workers (61%) were skin prick positive to a laboratory prepared caddis fly antigen (LCFA) made from the remains of caddis flies present in the plant and 11 (39%) had positive reactions to a commercial caddis fly antigen (CCFA). Workers stationed in heavily exposed areas were 3.7 times as likely to have a positive response to the LCFA (p = 0.009) and 5.3 times as likely to have a positive response to the CCFA (p = 0.036). 13 (46%) of survey respondents reported three or more work related symptoms. 10 (91%) CCFA positive workers reported three or more work related symptoms. Pulmonary function studies revealed slight, but not significantly decreased forced vital capacity (FVC), forced expiratory volume in one second (FEV1), and FEV1/FVC ratios in workers who were skin test positive to either caddis fly preparation when compared with those who were negative. One worker who was skin test positive to both antigens had a cross shift fall in FEV1 of 20% predicted. Occupational allergy to caddis flies proved to be a significant health problem at this work site.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimating Efficiency of Thermal and Hydroelectric Power Plants in Iranian Provinces

This paper aims at estimating the efficiency of hydroelectric power plants (renewable energy resources) and thermal power plant (non-renewable energy resources) in Iranian provinces. Data Envelopment Analysis (DEA) approaches is applied to estimate the efficiency. The network is modeled as a linear system with multiple inputs and one output. Fuel cost, labor force, operation cost are used as in...

متن کامل

An Overview of Hydroelectric Power Plant: Operation, Modeling, and Control

Renewable energy provides twenty percent of electricity generation worldwide. Hydroelectric power is the cheapest way to generate electricity today. It is a renewable source of energy and provides almost one-fifth of electricity in the world. Also, it generates electricity using a renewable natural resource and accounting for six percent of worldwide energy supply or about fifteen percent of th...

متن کامل

Submitting an automation method for detection cavitations in hydro turbines considering sensitivity parameters (Sefidroud hydroelectric power plant dam)

In this research, submitting a method for evaluation of detection cavitation specifications and also automation of cavitation threshold has been investigated. The case study was based on Kaplan hydro turbine data located on Tarik hydropower plant at Sefidroud dam. The foundation of method was employment MATLAB program, sensor classification sensor locations and cavitation sensitivity. For train...

متن کامل

An Investigation of Health and Safety Measures in a Hydroelectric Power Plant

BACKGROUND Occupational risk management is known as a catalyst in generating superior returns for all stakeholders on a sustainable basis. A number of companies in Ghana implemented health and safety measures adopted from international companies to ensure the safety of their employees. However, there exist great threats to employees' safety in these companies. The purpose of this paper is to in...

متن کامل

Job Stress among Workers Exposed to Extremely Low Frequency Electric and Magnetic Fields in a Combined Cycle Power Plant

Introduction: Exposure to the low frequency electric and magnetic fields (ELF-EMF) is very common in workers occupied in the combined cycle power plant during work shifts  The present study aimed to measure ELF-EMF flux density among shift and non-shift workers, determine job stress among workers and office workers, and identify major factors associated with job stress in the studied groups. M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Occupational and environmental medicine

دوره 51 6  شماره 

صفحات  -

تاریخ انتشار 1994