Everolimus triggers cytokine release by macrophages: rationale for stents eluting everolimus and a glucocorticoid.
نویسندگان
چکیده
OBJECTIVE Stent-based delivery of the mammalian target of rapamycin (mTOR) inhibitor everolimus is a promising strategy for the treatment of coronary artery disease. We studied potential adverse effects associated with mTOR inhibition. METHODS AND RESULTS Macrophages in culture were either treated with everolimus or starved to inhibit mTOR. Everolimus led to inhibition of protein translation, activation of p38 MAPK, and the release of proinflammatory cytokines (eg, IL-6, TNFα) and chemokines (eg, MCP1, Rantes) before induction of autophagic death. These effects were also observed with rapamycin, but not after starvation. Everolimus-induced cytokine release was similar in macrophages lacking the essential autophagy gene Atg7 but was inhibited when macrophages were cotreated with p38 MAPK inhibitor SB202190 or the glucocorticoid clobetasol. Combined stent-based delivery of clobetasol and everolimus in rabbit plaques downregulated TNFα expression as compared with everolimus-treated plaques but did not affect the ability of everolimus to induce macrophage clearance. CONCLUSIONS mTOR inhibition by everolimus triggers cytokine release in macrophages through inhibition of protein translation and p38 activation. These findings provide a rationale for combined local treatment of atherosclerotic plaques with everolimus and an anti-inflammatory agent.
منابع مشابه
Three-year follow-up of patients with bifurcation lesions treated with sirolimus- or everolimus-eluting stents: SEAside and CORpal cooperative study.
INTRODUCTION AND OBJECTIVES To compare the 3-year incidence of major events in patients with bifurcation lesions treated with provisional sirolimus-eluting stents vs everolimus-eluting stents. METHODS A pooled analysis of 2 prospective randomized trials with similar methodology (SEAside and CORpal) was performed. In these trials, 443 patients with bifurcation lesions were randomly assigned to...
متن کاملEverolimus-Eluting versus Paclitaxel-Eluting Stents in Percutaneous Coronary Intervention: Meta-Analysis of Randomized Trials
Background. Individual randomized trials have suggested that everolimus-eluting stents may have improved clinical outcomes compared to paclitaxel-eluting stents, but individual trials are underpowered to examine outcomes such as mortality and very late stent thrombosis. Methods. Medline, Cochrane, and conference proceedings were searched for randomized trials comparing everolimus versus paclita...
متن کاملInterventional Cardiology Randomized Comparison of Everolimus-Eluting Stent Versus Sirolimus-Eluting Stent Implantation for De Novo Coronary Artery Disease in Patients With Diabetes Mellitus (ESSENCE-DIABETES) Results From the ESSENCE-DIABETES Trial
Background—Drug-eluting stents significantly improved angiographic and clinical outcomes compared with bare metal stents in diabetic patients. However, a comparison of everolimus-eluting stents and sirolimus-eluting stents in diabetic patients has not been evaluated. Therefore we compared effectiveness of everolimus-eluting stents and sirolimus-eluting stents in patients with diabetes mellitus....
متن کاملBare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis
OBJECTIVE To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. DESIGN Mixed treatment comparison meta-analysis of 258,544 patient years of follow-up from randomized trials. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and Central were searched for randomized trials comparing any of the Fo...
متن کاملUltrathin strut biodegradable polymer sirolimus-eluting stent versus durable polymer everolimus-eluting stent for percutaneous coronary revascularisation (BIOSCIENCE): a randomised, single-blind, non-inferiority trial.
BACKGROUND Refinements in stent design affecting strut thickness, surface polymer, and drug release have improved clinical outcomes of drug-eluting stents. We aimed to compare the safety and efficacy of a novel, ultrathin strut cobalt-chromium stent releasing sirolimus from a biodegradable polymer with a thin strut durable polymer everolimus-eluting stent. METHODS We did a randomised, single-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Arteriosclerosis, thrombosis, and vascular biology
دوره 32 5 شماره
صفحات -