Biologic Fixation through Bridge Plating for Comminuted Shaft Fracture of the Clavicle: Technical Aspects and Prospective Clinical Experience with a Minimum of 12-Month Follow-up

نویسندگان

  • Gu Hee Jung
  • Chang-Min Park
  • Jae-Do Kim
چکیده

For comminuted shaft fracture of clavicle, the operative goal, aside from sound bone healing without complications of direct reduction, is maintenance of the original length in order to maintain the normal biomechanics of adjacent joint. Our bridge plating technique utilizing distraction through a lumbar spreader was expected to be effective for restoring clavicular length with soft tissue preservation. However, there are two disadvantages. First, there is more exposure to radiation compared to conventional plating; and second, it is difficult to control the rotational alignment. Despite these disadvantages, our technique has important benefits, in particular, the ability to preserve clavicular length without soft tissue injury around the fracture site.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Comparison of Results of Treatment of Midshaft Clavicle Fracture between Operative Treatment with Plate and Non-Operative Treatment

Background:  Clavicle fractures are common and usually heal without complications. In this study, we evaluated the outcomes of non-operative versus operative management of displaced fractures.   Methods:  In a prospective clinical trial study, sixty-five patients with displaced clavicle mid-shaft fractures were nonrandomly divided in two treatment groups. The first group underwent non-operative...

متن کامل

Union Following Biological and Rigid Fixations of Distal Tibia Extra-articular Fractures

Background: Distal tibia fractures are among the most common bony injuries, with a significant rate of nonunion anddelayed union. There are multiple methods for the management of distal tibia fractures. Among the plating methods,there are bridge plating and compression plating techniques. There is still a lack of evidence about whether one methodhas a higher rate of union than...

متن کامل

Is plating of mid-shaft clavicular fractures possible with a conventional straight 3.5 millimeter locking compression plate?

OBJECTIVES Current literature describes improved clinical outcomes and a minor rate of pseudoarthrosis following operatively treated clavicular fractures. We investigated the feasibility of using a standard 3.5 mm AO locking compression plate (LCP) of adequate length for the stabilisation of mid-shaft fractures of the clavicle. METHODS The length and acromial and diaphyseal curvature depths w...

متن کامل

بررسی تکنیک صفحه‌گذاری بیولوژیک در شکستگی‌های چند قطعه‌ای ساب‌تروکانتریک استخوان ران

Background: Comminuted subtrochanteric fractures have been a challenge for orthopedic surgeons in terms of appropriate reduction and stable fixation. Numerous methods have been used for the fixation of comminuted subtrochanteric fractures among which some are accompanied with technical difficulties and complications of their own. Regarding the results of previous studies, we decided to evaluate...

متن کامل

Bridge-plating osteosynthesis of 20 comminuted subtrochanteric fractures with dynamic hip screw.

BACKGROUND A prospective clinical trial was conducted to evaluate the conjunctive use of an extramedullary device and the bridge-plating technique in the treatment of comminuted subtrochanteric fractures with major extension into the femoral shaft. METHODS A Winquist criteria was used to classify 3 fracture patterns. The type 3 fractures were excluded from this study because of great extent o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2013