Experimental MgI oscillator strengths and radiative lifetimes for astrophysical applications on metal-poor stars - New data for the MgI

نویسنده

  • S. G. Ryan
چکیده

Context. The stellar abundance ratio of Mg/Fe is an important tool in diagnostics of galaxy evolution. In order to make reliable measurements of the Mg abundance of stars, it is necessary to have accurate values for the oscillator strength ( f -value) of each of the observable transitions. In metal-poor stars the Mg i 3p–4s triplet around 5175 Å (Fraunhofer’s so-called b lines) are the most prominent magnesium lines. The lines also appear as strong features in the solar spectrum. Aims. We present new and improved experimental oscillator strengths for the optical Mg i 3p–4s triplet, along with experimental radiative lifetimes for six terms in Mg i. With these data we discuss the implications on previous and future abundance analyses of metal-poor stars. Methods. The oscillator strengths have been determined by combining radiative lifetimes with branching fractions, where the radiative lifetimes are measured using the laser induced fluorescence technique and the branching fractions are determined using intensity calibrated Fourier Transform (FT) spectra. The FT spectra are also used for determining new accurate laboratory wavelengths for the 3p–4s transitions. Results. The f -values of the Mg i 3p–4s lines have been determined with an absolute uncertainty of 9%, giving an uncertainty of ±0.04 dex in the log g f values. Compared to values previously used in abundance analyses of metal-poor stars, rescaling to the new values implies an increase of typically 0.04 dex in the magnesium abundance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental Mg I oscillator strengths and radiative lifetimes for astrophysical applications on metal - poor stars New data for the Mg I b triplet

Context. The stellar abundance ratio of Mg/Fe is an important tool in diagnostics of galaxy evolution. In order to make reliable measurements of the Mg abundance of stars, it is necessary to have accurate values for the oscillator strength ( f -value) of each of the observable transitions. In metal-poor stars the Mg i 3p–4s triplet around 5175 Å (Fraunhofer’s so-called b lines) are the most pro...

متن کامل

CALCULATIONS OF OSCILLATOR STRENGTHS AND LIFETIMES OF CuI, AgI AND AuI USING COULOMB APPROXIMATION

Oscillator strengths and lifetimes of all energy levels of CuI, Agl and AuI were calculated using the Coulomb approximation (for The first time), and then compared with available data

متن کامل

Oscillator strengths for lines of astrophysical interest in Rh II⋆

Aims. This work reports oscillator strengths for transitions of astrophysical interest in singly ionized rhodium. Methods. Seventeen radiative lifetimes in Rh have been measured with the time-resolved laser-induced fluorescence technique and combined with theoretical branching fractions calculated using a relativistic Hartree-Fock model including core-polarization effects to obtain oscillator s...

متن کامل

Barley Productivity Decomposition in Iran: Comparison of TT, GI, MGI, and GTTI Approaches

In this paper, the authors present new indices for estimating technical change, return to scale, and TFP growth, as well as its decomposition. These indices, Modified General Index (MGI), Generalized Modified General Index (GMGI), and General Time Trend index (GTTI), are generalization of General Index approaches. These approaches were used for productivity decomposition of Iran's barely produc...

متن کامل

Experimental Ti I oscillator strengths and their application to cool star analysis

We report experimental oscillator strengths for 88 Ti I transitions covering the wavelength range 465 to 3 892 nm, 67 of which had no previous experimental values. Radiative lifetimes for thirteen energy levels, including the low energy levels 3d( F) 4s4p ( P) z 5D◦j , have been measured using time resolved laser induced fluorescence. Intensity calibrated Ti I spectra have been measured using F...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016