Shock or no shock - a question of philosophy or should intraoperative implantable cardioverter defibrillator testing be recommended?
نویسندگان
چکیده
OBJECTIVES Implantation of implantable cardioverter defibrillators (ICDs) in patients with a high risk for life-threatening ventricular arrhythmias is a standard therapy. The development of new ICD leads, shock algorithms, high-energy defibrillators and rapid energy supply has improved the devices. Nevertheless, the discussion regarding 'shock or no shock' to test the system intraoperatively has not silenced yet. METHODS In this study, all 718 patients (60.0 ± 14.2 years old, 570 male) who were treated with a first ICD at our institution since 2005 were analysed. The indication for implantation was primarily prophylactic in 511 patients (71.3%). Underlying diseases included ischaemic cardiomyopathy (358 patients, 50%), dilated cardiomyopathy (270 patients, 37.7%) and others (12.3%). Mean ejection fraction was 27.4 ± 11.8%. Intraoperative ventricular fibrillation was induced with a T-wave shock or burst stimulation. The primary end-point was failing the initial intraoperative testing. RESULTS During the initial testing, 28 patients (3.9%) had a defibrillation threshold (DFT) >21 J. The mean age of these patients was 51 ± 14 years, ranging from 22 to 71 years, 20 were male, and the ejection fraction was 23.8 ± 11.8%. The indication for ICD implantation was prophylactic in 13 patients. Twenty-one of the 28 patients suffered from dilated cardiomyopathy, whereas seven patients had ischaemic cardiomyopathy. Twenty-four ICDs were implanted on the left side and four on the right side. None of the patients had been treated with amiodarone at the time of implantation. All patients achieved a sufficient DFT ≤ 21 J by changing the ICD leads, device repositioning and/or optimizing the shock configuration. CONCLUSIONS The standard of care intraoperative ICD testing remains necessary.
منابع مشابه
Intraoperative Defibrillation Testing of Subcutaneous Implantable Cardioverter‐Defibrillator Systems—A Simple Issue?
BACKGROUND The results of the recently published randomized SIMPLE trial question the role of routine intraoperative defibrillation testing. However, testing is still recommended during implantation of the entirely subcutaneous implantable cardioverter-defibrillator (S-ICD) system. To address the question of whether defibrillation testing in S-ICD systems is still necessary, we analyzed the dat...
متن کاملThe effect of education based on Orem’s self-care model on emotional reactions in patients with Implantable Cardioverter Defibrillator (ICD)
Abstract Aim. The purpose of this study was to examine the effect of education based on Orem’s self-care model on emotional reactions in people with Implantable Cardioverter Defibrillator (ICD). Background. ICD shock is unpredictable and associated with physical pain. After receiving shock, some patients find serious psychological problems such as anxiety, depression and stress. According to Or...
متن کاملInductionless or limited shock testing is possible in most patients with implantable cardioverter- defibrillators/cardiac resynchronization therapy defibrillators: results of the multicenter ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduction Evaluation With Implantable Cardioverter-Defibrillator Implantations).
BACKGROUND Implantable cardioverter-defibrillators and cardiac resynchronization therapy defibrillators have relied on multiple ventricular fibrillation (VF) induction/defibrillation tests at implantation to ensure that the device can reliably sense, detect, and convert VF. The ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduc...
متن کاملEffects of implantable cardioverter defibrillator implantation and shock application on biochemical markers of myocardial damage.
BACKGROUND Implantable cardioverter defibrillator (ICD) implantation is a common approach in patients at high risk of sudden cardiac death. To check for normal function, it is necessary to test the ICD. For this purpose, repetitive induction and termination of ventricular fibrillation by direct current shocks is required. This may lead to minor myocardial damage. Cardiac troponin T (cTnT) and I...
متن کاملTHE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL
Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Interactive cardiovascular and thoracic surgery
دوره 16 3 شماره
صفحات -
تاریخ انتشار 2013