In vivo contact force analysis and correlation with tissue impedance during left atrial mapping and catheter ablation of atrial fibrillation.
نویسندگان
چکیده
BACKGROUND The aim of this study was to evaluate in vivo contact force (CF) and the correlation of CF with impedance during left atrial 3-dimensional electroanatomical mapping and ablation. METHODS AND RESULTS CF during point-by-point left atrial mapping was assessed in 30 patients undergoing atrial fibrillation ablation. Operators were blinded to the real-time CF data. Data were analyzed according to 11 predefined areas in the left atrial and 6 segments around the ipsilateral pulmonary veins. A total of 3475 mapping and 878 ablation points were analyzed. Median CF during mapping was 14.0g (6.5-26.2; q1-q3), ranging from 5.1g at the ridge to 29.8g at the roof. Median CF at the ridge and mitral isthmus were 5.1g and 6.9g, respectively. Extremely high CF ≥100g was noted in 24 points (0.7%). Median CFs during ablation around the right and left pulmonary veins were 22.8g (12.6-37.9; q1-q3) and 12.3g (6.9-30.2; q1-q3), respectively. The lowest median CFs were recorded at the anterior-superior and anterior-inferior segments of the left pulmonary veins (7.2g and 7.9g). Impedance values during mapping and impedance fall during ablation correlated with the applied CF (R(2)=0.16; P<0.001 and R(2)=0.04; P<0.001) although there was significant overlap. CONCLUSIONS Excessively high and low CF values can be observed during left atrial mapping and ablation. The low CF obtained at the mitral isthmus and anterior segments of the left pulmonary veins may explain why reconnection after ablation occurs more frequently at these sites. CF and impedance do correlate; however, the impedance for a given CF ranges widely, limiting its use in clinical practice.
منابع مشابه
Locations of high contact force during left atrial mapping in atrial fibrillation patients: electrogram amplitude and impedance are poor predictors of electrode-tissue contact force for ablation of atrial fibrillation.
BACKGROUND During radiofrequency ablation, high electrode-tissue contact force (CF) is associated with increased risk of steam pop and perforation. The purpose of this study, in patients undergoing ablation of paroxysmal atrial fibrillation, was to: (1) identify factors producing high CF during left atrial (LA) and pulmonary vein mapping; (2) determine the ability of atrial potential amplitude ...
متن کاملThe Role Of Contact Force In Atrial Fibrillation Ablation.
During radiofrequency (RF) ablation, low electrode-tissue contact force (CF) is associated with ineffective RF lesion formation, whereas excessive CF may increase the risk of steam pop and perforation. Recently, ablation catheters using two technologies have been developed to measure real-time catheter-tissue CF. One catheter uses three optical fibers to measure microdeformation of a deformable...
متن کاملContact force technology in catheter ablation of atrial fibrillation
Catheter ablation of atrial fibrillation (AF) has an indisputable value in the treatment of patients with symptomatic drug refractory AF. Nowadays, special interest is paid to improve the efficacy and the safety of the procedure and new approaches allowing better understanding of the lesions creation and its control have been developed. A lot of factors including power and duration of energy de...
متن کاملContact Force Assessment In Catheter Ablation Of Atrial Fibrillation.
The efficacy of catheter ablation of atrial fibrillation (AF) remains limited. Increase of success would require more durable lesions without increased risk of complications, such as of steam pop and cardiac perforation. Recently, novel technologies have been developed to estimate real-time catheter-tissue contact force (CF). This paper reviews three available tools for assessment of CF and dat...
متن کاملTarget indices for clinical ablation in atrial fibrillation: insights from contact force, electrogram, and biophysical parameter analysis.
BACKGROUND In animal studies of radiofrequency ablation, lesion sizes plateau as the maximum lesion size is reached for an ablation. Lesion parameters are not available in clinical ablations, but preclinical work suggests that these correlate with impedance drop and electrogram attenuation. Characterization of the relationships between catheter contact force, ablation duration, and these surrog...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Arrhythmia and electrophysiology
دوره 7 1 شماره
صفحات -
تاریخ انتشار 2014