Effect of Topical Anaesthetics on Interstitial Colloid Osmotic Pressure in Human Subcutaneous Tissue Sampled by Wick Technique

نویسندگان

  • Hans Jørgen Timm Guthe
  • Torbjørn Nedrebø
  • Olav Tenstad
  • Helge Wiig
  • Ansgar Berg
چکیده

OBJECTIVES To measure colloid osmotic pressure in interstitial fluid (COP(i)) from human subcutaneous tissue with the modified wick technique in order to determine influence of topical application of anaesthetics, dry vs. wet wick and implantation time on COP(i). MATERIAL AND METHODS In 50 healthy volunteers interstitial fluid (IF) was collected by subcutaneous implantation of multi-filamentous nylon wicks. Study subjects were allocated to two groups; one for comparing COP(i) obtained from dry and saline soaked wicks, and one for comparing COP(i) from unanaesthetized skin, and skin after application of a eutectic mixture of local anaesthetic (EMLA®, Astra Zeneca) cream. IF was sampled from the skin of the shoulders, and implantation time was 30, 60, 75, 90 and 120 min. Colloid osmotic pressure was measured with a colloid osmometer. Pain assessment during the procedure was compared for EMLA cream and no topical anaesthesia using a visual analogue scale (VAS) in a subgroup of 10 subjects. RESULTS There were no significant differences between COP(i) obtained from dry compared to wet wicks, except that the values after 75 and 90 min. were somewhat higher for the dry wicks. Topical anaesthesia with EMLA cream did not affect COP(i) values. COP(i) decreased from 30 to 75 min. of implantation (23.2 ± 4.4 mmHg to 19.6 ± 2.9 mmHg, p = 0.008) and subsequently tended to increase until 120 min. EMLA cream resulted in significant lower VAS score for the procedure. CONCLUSION COP(i) from subcutaneous tissue was easily obtained and fluid harvesting was well tolerated when topical anaesthetic was used. The difference in COP(i) assessed by dry and wet wicks between 75 min. and 90 min. of implantation was in accordance with previous reports. The use of topical analgesia did not influence COP(i) and topical analgesia may make the wick technique more acceptable for subjects who dislike technical procedures, including children. TRIAL REGISTRATION ClinicalTrials.gov NCT01044979.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interstitial gel swelling pressure in human subcutaneous tissue measured with a cotton wick.

1. A cotton wick probe has been used to measure the pressure in subcutaneous interstitial tissues of man. 2. The probe was inserted with minimal trauma into a plane of natural dissection at the level of the deep fascia in three sites: dorsum of the hand and foot, and the forearm. 3. The pressure was subatmospheric on every occasion (mean pressure : hand, -3-015SD 0.50 cmH,O; foot, -3.545SD 1-74...

متن کامل

Isolation of interstitial fluid from skeletal muscle and subcutis in mice using a wick method.

Until recent years, mice were sparsely used in physiological experiments, and therefore, data on the basic cardiovascular parameters of mice are lacking. Our aim was to gain access to interstitial fluid and thereby study transcapillary fluid dynamics in this species. Using a modified wick method, we were able to isolate interstitial fluid from subcutis and skeletal muscle in mice. Three-strande...

متن کامل

Kappa Delta Award paper. Tissue fluid pressures: from basic research tools to clinical applications.

The two basic research tools developed to measure tissue fluid pressure (wick catheter) and osmotic pressure (colloid osmometer) have undergone extensive validation and refinement over the past 20 years. Using these techniques, basic science investigations were undertaken of edema in Amazon reptiles, pressure-volume relations in animals and plants, adaptive physiology of Antarctic penguins and ...

متن کامل

Acute peritoneal dialysis in rats results in a marked reduction of interstitial colloid osmotic pressure.

The aim of this study was to investigate whether the interstitial colloid osmotic pressure (COP(i)) of peritoneum is of importance for peritoneal fluid reabsorption during peritoneal dialysis (PD). For testing this hypothesis, a method to isolate interstitial fluid from the peritoneal membrane and to measure the interstitial COP(i) in the normal peritoneum and directly after the initiation of P...

متن کامل

Transcapillary fluid flux and inflammatory response during neonatal therapeutic hypothermia: an open, longitudinal, observational study

BACKGROUND Therapeutic hypothermia is neuroprotective in asphyxiated neonates by counteracting mechanisms contributing to brain injury. Although an initial increased permeability is part of an inflammatory reaction and thereby a natural healing process, an excessive endothelial permeability with edema formation may result in impaired hemodynamics. Reduced permeability may, however, benefit heal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012