Cyclic fatigue resistance of rotary NiTi instruments after simulated clinical use in curved root canals.
نویسندگان
چکیده
The aim of this study was to assess cyclic fatigue resistance in rotary nickel-titanium instruments after simulated clinical use in curved root canals (40-degree, 5-mm radius curve). Thirty-six RaCe rotary NiTi files, size #5, taper 0.04, were divided into 3 groups: Groups A, B and C with one, three and five cycles of use, respectively. Time to failure was recorded with a stopwatch in seconds and subsequently converted to number of cycles to fracture. The data were analyzed statistically by ANOVA and Tukey's test (α=0.05). Five sets of clinically used files (group C) reached significantly lower cycle-numbers before fracture (mean=197.5 cycles) when compared with one set of clinically used files (mean=309.2) and three sets (mean=287.5). Results showed that the number of simulated clinical uses of RaCe instruments for shaping curved canals affects adversely the fatigue resistance of these instruments after five uses.
منابع مشابه
Comparison of cyclic fatigue and torsional resistance in reciprocating single-file systems and continuous rotary instrumentation systems.
As compared with continuous rotary systems, reciprocating motion is believed to increase the fatigue resistance of NiTi instruments. We compared the cyclic fatigue and torsional resistance of reciprocating single-file systems and continuous rotary instrumentation systems in simulated root canals. Eighty instruments from the ProTaper Universal, WaveOne, MTwo, and Reciproc systems (n = 20) were s...
متن کاملCyclic fatigue resistance of Mtwo NiTi rotary instruments used by experienced and novice operators – an in vivo and in vitro study
BACKGROUND The aim of the present study was to evaluate the cyclic fatigue resistance of Mtwo NiTi rotary instruments after clinical use by 1 experienced and 1 novice operator. MATERIAL/METHODS Cyclic fatigue testing of instruments was performed on tapered artificial canals with a 5 mm radius of curvature and 60° angle of curvature. Twenty Mtwo instruments for each size were selected and divid...
متن کاملShaping Ability of NiTi Rotary versus Stainless-Steel Hand Instruments in Curved Root Canals of Extracted Teeth
Introduction: The purpose of this in-vitro study was to compare shaping ability of NiTi rotary Mtwo and FlexMaster with stainless steel hand K-Flexofile in curved root canals of extracted teeth. Materials and Methods: Mesiobuccal canals of 45 mandibular molar teeth were balanced into three groups of 15 each, with respect to the Schneider angle, canal access angle, height, dis-tance and radiu...
متن کاملCyclic fatigue behavior of nickel-titanium dental rotary files in clinical simulated root canals.
BACKGROUND/PURPOSE Dental rotary instruments can be applied in multiple conditions of canals, but unpredictable fatigue fracture may happen. This study evaluated the fatigue lives of two batches of nickel-titanium (NiTi) dental rotary files operating in clinically simulated root canals. METHODS Single-step cyclic fatigue tests were carried out to assess the performance of two batches of NiTi ...
متن کاملA dozen ways to prevent nickel-titanium rotary instrument fracture.
BACKGROUND and Overview. With the increased use of nickel-titanium (NiTi) rotary instruments for root canal preparation in endodontics, instrument fracture has become more prevalent. Extensive research has been conducted on the physical properties and mechanical characteristics of NiTi rotary instruments, as well as the factors that can contribute to instrument failure. NiTi rotary instruments ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Brazilian dental journal
دوره 24 2 شماره
صفحات -
تاریخ انتشار 2013