Imaging assessment of a portable hemodialysis device: detection of possible failure modes and monitoring of functional performance

نویسندگان

  • Olufoladare G. Olorunsola
  • Steven H. Kim
  • Ryan Chang
  • Yuo-Chen Kuo
  • Steven W. Hetts
  • Alex Heller
  • Rishi Kant
  • Maythem Saeed
  • William H. Fissell
  • Shuvo Roy
  • Mark W. Wilson
چکیده

BACKGROUND The purpose of this study was to investigate the utility and limitations of various imaging modalities in the noninvasive assessment of a novel compact hemodialyzer under development for renal replacement therapy, with specific aim towards monitoring its functional performance. METHODS The prototype is a 4×3×6 cm aluminum cartridge housing "blood" and "dialysate" flow paths arranged in parallel. A sheet of semipermeable silicon nanopore membranes forms the blood-dialysate interface, allowing passage of small molecules. Blood flow was simulated using a peristaltic pump to instill iodinated contrast through the blood compartment, while de-ionized water was instilled through the dialysate compartment at a matched rate in the countercurrent direction. Images were acquired under these flow conditions using multi-detector computed tomography (MDCT), fluoroscopy, high-resolution quantitative computed tomography (HR-QCT), and magnetic resonance imaging (MRI). MDCT was used to monitor contrast diffusion efficiency by plotting contrast density as a function of position along the path of flow through the cartridge during steady state infusion at 1 and 20 mL/min. Both linear and exponential regressions were used to model contrast decay along the flow path. RESULTS Both linear and exponential models of contrast decay appeared to be reasonable approximations, yielding similar results for contrast diffusion during a single pass through the cartridge. There was no measurable difference in contrast diffusion when comparing 1 mL/min and 20 mL/min flow rates. Fluoroscopy allowed a gross qualitative assessment of flow within the device, and revealed flow inhomogeneity within the corner of the cartridge opposite the blood inlet port. MRI and HR-QCT were both severely limited due to the paramagnetic properties and high atomic number of the target material, respectively. During testing, we encountered several causes of device malfunction, including leak formation, trapped gas, and contrast-mediated nanopore clogging. We illustrate the imaging manifestations of each. CONCLUSIONS Despite the inherent challenges in imaging a predominantly metallic device, some modalities show potential in the non-invasive assessment of a novel compact hemodialyzer. The approaches described here could potentially be translated to device evaluation in the implanted setting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low-cost Vector Network Analyzer for Biomedical Applications

A low-cost and portable vector network analyzer (VNA) which covered operating frequency between 1MHz to 3GHz is used for vector reflection coefficient and standing wave ratio (swr) of the various microstrip antennas. This paper presents measurements of various ultra wideband (uwb) microstrip antennas for applications in biomedical field. Selection of antenna is an important key for detection of...

متن کامل

Evaluation of Cardiac Mitochondrial Function by a Nuclear Imaging Technique using Technetium-99m-MIBI Uptake Kinetics

Mitochondria play an important role in energy production for the cell. The proper function of a myocardial cell largely depends on the functional capacity of the mitochondria.  Therefore it is necessary to establish a novel and reliable method for a non-invasive assessment of mitochondrial function and metabolism in humans. Although originally designed for evaluating myocardial perfusion, 99mTc...

متن کامل

Optimized Blood Volume Monitoring during Hemodialysis Procedure based on Ultrasonic Speed Measurement

Fast reduction of blood water volume due to ultra-filtration via hemodialysis machine and critical threshold of blood water volume can result in clinical complications such as hypotension. When blood water volume reduces during hemodialysis process, the concentration of blood forming elements will increase. One of the methods for the monitoring of the concentration changes is ultrasonic speed m...

متن کامل

الگوریتم جدید انتخاب حالت داخل فریمی سریع در استاندارد کدگذاری ویدیویی H.264/AVC

By the increasing of video communication in portable and functional devices, encoders design with low complexity and high performance are required. H.264 / AVC standard offers higher compression efficiency than previous standards. But this standard by employing several powerful coding techniques, considerably increased complexity at the encoder. This paper presents a new algorithm to reduc...

متن کامل

Risk Assessment of Drug Management Process in Women Surgery Department of Qaem Educational Hospital (QEH) Using HFMEA Method (2013)

Evaluation and improvement of drug management process is essential for patient safety. The present study was performed whit the aim of assessing risk of drug management process in Women Surgery Department of QEH using HFMEA method in 2013. A mixed method was used to analys failure modes and their effects with HFMEA. To classify failure modes; nursing errors in clinical management model, for cla...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2014