An electrostatic autoresonant ion trap mass spectrometer.

نویسندگان

  • A V Ermakov
  • B J Hinch
چکیده

A new method for ion extraction from an anharmonic electrostatic trap is introduced. Anharmonicity is a common feature of electrostatic traps which can be used for small scale spatial confinement of ions, and this feature is also necessary for autoresonant ion extraction. With the aid of ion trajectory simulations, novel autoresonant trap mass spectrometers (ART-MSs) have been designed based on these very simple principles. A mass resolution approximately 60 is demonstrated for the prototypes discussed here. We report also on the pressure dependencies, and the (mV) rf field strength dependencies of the ART-MS sensitivity. Importantly the new MS designs do not require heavy magnets, tight manufacturing tolerances, introduction of buffer gases, high power rf sources, nor complicated electronics. The designs described here are very inexpensive to implement relative to other instruments, and can be easily miniaturized. Possible applications are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trajectory compensation in an autoresonant trap mass spectrometer.

The auto-resonant trap mass spectrometer, ART-MS, utilizes electrostatic ion trapping within an anharmonic potential well. Ions are detected after mass selective trap ejection with auto-resonant driving employing only low-power rf electronics. We identify the major limiting factor in the mass resolution of these instruments. Whilst keeping in the spirit of maintaining a rapid scan rate, low cos...

متن کامل

Performance evaluation of a hybrid linear ion trap/orbitrap mass spectrometer.

Design and performance of a novel hybrid mass spectrometer is described. It couples a linear ion trap mass spectrometer to an orbitrap mass analyzer via an rf-only trapping quadrupole with a curved axis. The latter injects pulsed ion beams into a rapidly changing electric field in the orbitrap wherein they are trapped at high kinetic energies around an inner electrode. Image current detection i...

متن کامل

Negative mass instability for interacting particles in a 1D box: theory and application.

We demonstrate that the synchronization effect observed [Pedersen et al., Phys. Rev. Lett. 87, 055001 (2001)]], when a bunch of ions oscillates between two mirrors in an electrostatic ion beam trap, can be explained as a negative mass instability. We derive simple necessary conditions for the existence of a regime in which this dispersionless behavior occurs and demonstrate that in this regime,...

متن کامل

Autoresonant-spectrometric determination of the residual gas composition in the ALPHA experiment apparatus.

Knowledge of the residual gas composition in the ALPHA experiment apparatus is important in our studies of antihydrogen and nonneutral plasmas. A technique based on autoresonant ion extraction from an electrostatic potential well has been developed that enables the study of the vacuum in our trap. Computer simulations allow an interpretation of our measurements and provide the residual gas comp...

متن کامل

Systematic comparison of a two-dimensional ion trap and a three-dimensional ion trap mass spectrometer in proteomics.

The utility and advantages of the recently introduced two-dimensional quadrupole ion trap mass spectrometer in proteomics over the traditional three-dimensional ion trap mass spectrometer have not been systematically characterized. Here we rigorously compared the performance of these two platforms by using over 100,000 tandem mass spectra acquired with identical complex peptide mixtures and acq...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 81 1  شماره 

صفحات  -

تاریخ انتشار 2010