BACKGROUND The rabbit is a common animal model for ophthalmic research, especially corneal research. Ocular structures grow rapidly during the early stages of life. It is unclear when the rabbit cornea becomes mature and stabilized. We investigated the changes of keratometry, refractive state and central corneal thickness (CCT) with age. In addition, we studied the intra- and inter-observer reproducibility of anterior chamber depth (ACD) and anterior chamber width (ACW) measurements in rabbits using anterior segment-optical coherence tomography (AS-OCT). RESULTS The growth of New Zealand White rabbits (n = 16) were monitored from age 1 to 12 months old. Corneal keratometric and refractive values were obtained using an autorefractor/keratometer, and CCT was measured using an AS-OCT. Keratometry and CCT changed rapidly from 1 to 7 months and appeared to be stabilizing after 8 months. The reduction of corneal curvature was approximately 1.36 diopter (D)/month from age 1 to 7 months, but the change decelerated to 0.30 D/month from age 8 to 12 months. An increase of 10 μm/month in CCT was observed from age 1 to 7 months, but the gain was reduced to less than 1 μm/month from age 8 to 12 months. There was a hyperopic shift over the span of 12 months, albeit the increase in spherical equivalent was slow and gradual. Rabbits of random age were then selected for 2 repeated ACD and ACW measurements by 2 independent and masked observers. Bland-Altman plots revealed a good agreement of ACD and ACW measurements inter- and intra-observer and the ranges of 95% limit of agreement were acceptable from a clinical perspective. CONCLUSIONS Corneal keratometry, spherical equivalent refraction and CCT changed significantly during the first few months of life of rabbits. Young rabbits have been used in a large number of eye research studies. In certain settings, the ocular parametric changes are an important aspect to note as they may alter the findings made in a rabbit experimental model. In this study, we have also demonstrated for the first time a good between observer reproducibility of measurements of ocular parameters in an animal model by using an AS-OCT.
منابع مشابه
Dynamic age-related changes of extracellular field potential of isolated AV-node of rabbit
Introduction: Developmental changes in atrioventricular nodal conduction time and refractoriness have been shown in several studies. Prevalence of atrioventricular nodal reentrant tachycardia (AVNRT) is clearly age-dependent. The purpose of this study was to determine developmental changes of basic and frequency-dependent electrophysiological properties of the atrioventricular node (AV-node)...
متن کاملRadiographic Measurement of Vertebral Heart Scale (VHS) in New Zealand White Rabbits
Objective- The aim of the present survey was to evaluate whether the results of cardiac measurements using the VHS are a useful indicator of the origin of normal rabbits. Design- Experimental study. Animals- Forty seven adult healthy New Zealand White rabbits (25 male, 22 female) with age 10-18 months and weight 1.5-2.5 Kg. Procedures- To assess the influence of breed on the vertebral heart ...
متن کاملOcular Ultrasonographic Features in Iranian Native Donkey
Objective- The aim of this study was to evaluate ultrasonographic appearance of the normal eye and obtaining reference values of ocular structures in Iranian native donkey. Design- Experimental study. Animals- Five Iranian native donkeys. Procedures- After preparation of the animals, ocular structures were ima...
متن کاملOcular Dorzolamide Nanoliposomes for Prolonged IOP Reduction: in-vitro and in-vivo Evaluation in Rabbits
Dorzolamide ophthalmic drop is one of the most common glaucoma medications but it has a short residence time in the eye. The aim of this study is to develop ocular dorzolamide HCl nanoliposomes (DRZ – nanoliposomes) and to evaluate their potential use for the treatment of ocular hypertension. Nanoliposomes were prepared using Reverse-phase evaporation vesicle (REV) and thin layer hydration (TLH...
متن کاملPossibility and Reproducibility of Renal Assessing and Size Measurement by Three- Dimensional vs Two- Dimensional Ultrasounographv in Dogs
Objective- To determine the possibility and reproducibility of three-dimensional ultrasonography (3DUS)and comparison of the achieved measurements to normal two-dimensional ultrasonography (2DCS)Design- Descriptive studyAnimals- 10 young mixed normal dogs, age 1.5-2.5 year, weighing 9.7-12 kg Procedure- Renal width, length, and depth measured in coron al and transverse sections. The measurement...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 8 شماره
صفحات -
تاریخ انتشار 2012