Vibration perception thresholds in workers with long term exposure to lead.
نویسندگان
چکیده
OBJECTIVES To evaluate the impact of long term occupational exposure to lead on function of the peripheral nervous system as reflected by vibration perception threshold (VPT), measured with a portable vibrameter. METHODS 217 Workers in a lead battery factory were required to have an annual blood lead measurement during each of the 5 years preceding this study. All were invited to take the VPT test. A total of 206 workers were studied. The associations were analysed between VPTs and current blood lead concentration, mean concentration of blood lead over the past 5 years, maximum blood lead concentration during the past 5 years, index of cumulative blood lead (ICL), time weighted index of cumulative blood lead (TWICL), and percentage of lifespan spent at work in the plant, as well as the other potential confounders. Ordinary multiple regressions, generalised additive models, and hockey stick regression analyses were used to explore the potential existence of a threshold effect of blood lead variables on VPT. RESULTS VPT at a frequency of 220 Hz ranged from 6 to 100 (10(-2) g, or 0.098 m/s(2)) with a mean (SD) of 19.8 (14.2) for the feet and from 4 to 43 with a mean (SD) of 10.2 (6.1) for the hands. The five variables of exposure to lead were all significantly correlated with VPT of the feet but not the hands. In multiple linear regression analyses, the mean of the blood lead concentrations and the TWICL were significantly associated with VPT of the feet. The relation between VPT of the feet and mean blood lead was shown to be a J shaped curve with a generalised additive model and local smoothing technique. In the hockey stick regression, evidence was found of a threshold effect at a mean blood lead concentration of 31 microgram/dl. Above this threshold it was estimated that each increase of 1 microgram/dl mean blood lead over 5 years would increase VPT of the feet by 0.29 (10(-2) g) or 0.028 m/s(2) (at a frequency of 220 Hz) with other potential confounders held constant. CONCLUSION This study suggests that measurement of vibration sensory threshold is a relatively effective tool for detecting lead neuropathy in field studies, and that lead might cause sensory neuropathy with an effect threshold corresponding to a 5 year mean blood lead concentration of 31 microgram/dl.
منابع مشابه
Effects of low level exposure to lead on neurophysiological functions among lead battery workers.
OBJECTIVES Assessment of neurophysiological functions in workers with low level exposure to lead and evaluation of the efficacy of bone lead measurements in the prediction of effects of lead. METHODS Exposure to lead of 60 workers from a lead battery battery factory was estimated from historical blood lead measurements and analysis of lead in the tibial and calcaneal bones with x ray fluoresc...
متن کاملChanges over a workshift in aesthesiometric and vibrotactile perception thresholds of workers exposed to intermittent hand transmitted vibration from impact wrenches.
OBJECTIVES To investigate the changes over a workshift in fingertip tactile perception thresholds in users of impact wrenches exposed to intermittent hand transmitted vibration. A further aim was to assess the relation between acute changes in tactile sensation, sensorineural disorders, and vibration dose. METHODS The study populations consisted of 30 workers exposed to vibration (16 men and ...
متن کاملInvestigating the effect of sport and using anti-vibration gloves on the grip strength of workers exposed to the hand-arm vibration
Introduction: Long-term exposure to hand-arm vibration causes musculoskeletal disorders mainly in hand and shoulder. The purpose of this study was to determine the effect of sport and using anti-vibration gloves on the grip strength of workers exposed to the hand-arm vibration. Material and Methods: In this descriptive-interventionist study, 41workers working in one of the Isfahan metal indust...
متن کاملVibrotactile perception and effects of short-term exposure to hand-arm vibration.
This study clarifies whether the established frequency weighting procedure for evaluating exposure to hand-transmitted vibration can effectively evaluate the temporary changes in vibrotactile perception thresholds due to pre-exposure to vibration. In addition, this study investigates the relationship between changes of the vibrotactile perception thresholds and the normalized energy-equivalent ...
متن کاملTest-retest reliability of neurophysiological tests of hand-arm vibration syndrome in vibration exposed workers and unexposed referents
BACKGROUND Exposure to hand-held vibrating tools may cause the hand-arm vibration syndrome (HAVS). The aim was to study the test-retest reliability of hand and muscle strength tests, and tests for the determination of thermal and vibration perception thresholds, which are used when investigating signs of neuropathy in vibration exposed workers. METHODS In this study, 47 vibration exposed work...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Occupational and environmental medicine
دوره 57 9 شماره
صفحات -
تاریخ انتشار 2000