The Performance of the Four Anaerobic Blood Culture Bottles BacT/ALERT-FN, -FN Plus, BACTEC-Plus and -Lytic in Detection of Anaerobic Bacteria and Identification by Direct MALDI-TOF MS

نویسندگان

  • Mohammed Almuhayawi
  • Osman Altun
  • Adam Dilshad Abdulmajeed
  • Måns Ullberg
  • Volkan Özenci
  • Patrick CY Woo
چکیده

Detection and identification of anaerobic bacteria in blood cultures (BC) is a well-recognized challenge in clinical microbiology. We studied 100 clinical anaerobic BC isolates to evaluate the performance of BacT/ALERT-FN, -FN Plus (BioMérieux), BACTEC-Plus and -Lytic (Becton Dickinson BioSciences) BC bottles in detection and time to detection (TTD) of anaerobic bacteria. BACTEC Lytic had higher detection rate (94/100, 94%) than BacT/ALERT FN Plus (80/100, 80%) (p<0.01) in the studied material. There was no significant difference in detection of anaerobic bacteria among the remaining bottle types. The 67 anaerobic bacteria that signalled positive in all four bottle types were analyzed to compare the time to detection (TTD) and isolates were directly identified by MALDI-TOF MS. There was a significant difference in TTD among the four bottle types (p<0.0001). The shortest median TTD was 18 h in BACTEC Lytic followed by BacT/ALERT FN (23.5 h), BACTEC Plus (27 h) and finally BacT/ALERT FN Plus (38 h) bottles. In contrast, MALDI-TOF MS performed similarly in all bottle types with accurate identification in 51/67 (76%) BacT/ALERT FN, 51/67 (76%) BacT/ALERT FN Plus, 53/67 (79%) BACTEC Plus and 50/67 (75%) BACTEC Lytic bottles. In conclusion, BACTEC Lytic bottles have significantly better detection rates and shorter TTD compared to the three other bottle types. The anaerobic BC bottles are equally suitable for direct MALDI-TOF MS for rapid and reliable identification of common anaerobic bacteria. Further clinical studies are warranted to investigate the performance of anaerobic BC bottles in detection of anaerobic bacteria and identification by direct MALDI-TOF MS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Controlled clinical laboratory comparison of two supplemented aerobic and anaerobic media used in automated blood culture systems to detect bloodstream infections.

A 20-ml blood sample was collected from adult patients with suspected bloodstream infections and distributed equally into the four volume-controlled bottles of a blood culture set consisting of aerobic and anaerobic BACTEC Plus/F bottles and aerobic and anaerobic BacT/Alert FAN bottles. All bottles were incubated in their respective instruments for a standard 5-day protocol or until the instrum...

متن کامل

Controlled clinical comparison of the BacT/ALERT FN and the standard anaerobic SN blood culture medium.

To determine the optimal anaerobic companion bottle to pair with the BacT/ALERT (bioMerieux, Durham, N.C.) nonvented aerobic FA (FA) medium for recovery of pathogenic microorganisms from adult patients with bacteremia and fungemia, we compared the BacT/ALERT FN (FN) anaerobic bottle with the standard BacT/ALERT SN (SN) anaerobic bottle. Each bottle, FA, FN, and SN, was filled with 8 to 12 ml of...

متن کامل

Controlled clinical comparison of BacT/alert FA plus and FN plus blood culture media with BacT/alert FA and FN blood culture media.

New blood culture media containing antibiotic-binding polymeric beads have been developed for the BacT/Alert (bioMérieux, Inc., Durham, NC) blood culture system. To assess the performance of these new media, we compared the new BacT/Alert aerobic medium (FA Plus) with resins to BacT/Alert FA medium with activated charcoal and the new BacT/Alert anaerobic medium (FN Plus) to BacT/Alert FN medium...

متن کامل

Comparative recovery of microorganisms from BacT/ALERT plastic and glass FA and FN blood culture bottles.

bioMerieux, Inc., has recently introduced plastic bottles to replace glass bottles for use in the BacT/ALERT blood culture system. We compared the performance of the plastic to the glass bottles in a large clinical evaluation. Two blood cultures were collected from each patient, one using glass FA (aerobic) and FN (anaerobic) bottles and one using plastic FA and FN bottles. Of the 4,040 sets of...

متن کامل

Controlled comparison of the BacT/Alert and BACTEC 660/730 nonradiometric blood culture systems.

In a collaborative study at three university hospitals, the recovery of microorganisms and the speed of detection of microbial growth by the BacT/Alert (Organon Teknika Corporation, Durham, N.C.) and BACTEC 660/730 (Becton-Dickinson Diagnostic Instrument Systems, Sparks, Md.) nonradiometric blood culture systems were compared. A total of 5,918 comparisons were made between BacT/Alert aerobic an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015