Steady-state concentration distribution of artificial receptor and target analyte in plasticized PVC membrane between solutions differing in target analyte concentration.
نویسندگان
چکیده
A barbiturate receptor has proven effective in improving selectivity in solid-phase microextraction of barbiturates when doped into plasticized poly(vinyl chloride) (PVC). It would be beneficial to have selective extractions for any given organic species; however, the receptors do not exist. They will be found by screening of libraries of potential receptors; thus, a screening method is needed. It is important to screen the receptors in the medium in which they will work: plasticized PVC. We hypothesize that we can make receptors move in solution in response to the presence of a solute to which they bind. This work examines whether we can establish a sufficient free energy gradient for a good receptor to move to a predetermined place in space. A difference in the barbiturate solute (substrate or guest) concentration in solutions bathing the two sides of a plasticized PVC membrane containing the barbiturate receptor (or host) creates a spatial concentration gradient of the substrate in the membrane. This causes the receptor's chemical potential to vary across the membrane. Upon binding to the analyte, the receptor undergoes a local activity drop, which decreases its free energy. This process produces a flux of receptor to accumulate at place where there is a high substrate concentration. A concentration gradient of substrate can be maintained across the membrane at steady state. In membranes for which the formation of the complex is favored, the receptor responds to the gradient of substrate. In membranes for which binding is not favored, a gradient of substrate is completely ignored by the receptor. Thus, the receptor does respond to the gradient but only if the concentration gradient of guest corresponds to a chemical potential gradient.
منابع مشابه
Comparison of new optical sensor based on triazene ligand immobilized on PVC and triacetylcellulose membranes for Hg (II) Ion
For spectrophotometric analysis of Hg (II) ions, we have used and compared two membranes preparation methods using different polymer; one is poly(vinyl chloride) (PVC) and the other is triacetylcellulose (TAC). In the case of TAC membrane, it was treated with a ligand solution (1.166 × 10-3 mole L-1) in ethylenediamine at the ambient temperature for almost 2-5 min. However, in the case of PVC m...
متن کاملComparison of the vanadyl-selective electrodes prepared by sol–gel and PVC membrane techniques
Sol-gel and polymeric membrane electrodes, based on thiacalix[4]arene as a neutral carrier, weresuccessfully developed for the detection of VO2+ in aqueous solutions. The sol-gel and PVCmembrane electrodes exhibited linear response with Nernstian slopes of 29.3 and 28.4 mV perdecade, respectively, within the vanadyl ion concentration ranges from 1.0 × 10-6 to 1.0 × 10-1mol dm-3 and from 1.0 × 1...
متن کاملMonitoring of diisopropyl fluorophosphate hydrolysis by fluoride-selective polymeric films using absorbance spectroscopy.
In this study, a novel system for the detection and quantification of organofluorophosphonates (OFP) has been developed by using an optical sensing polymeric membrane to detect the fluoride ions produced upon OFP hydrolysis. Diisopropyl fluorophosphate (DFP), a structural analogue of type G chemical warfare agents such as Sarin (GB) and Soman (GD), is used as the surrogate target analyte. An op...
متن کاملCreating Diversified Response Profiles from a Single Quenchometric Sensor Element by Using Phase-Resolved Luminescence
We report a new strategy for generating a continuum of response profiles from a single luminescence-based sensor element by using phase-resolved detection. This strategy yields reliable responses that depend in a predictable manner on changes in the luminescent reporter lifetime in the presence of the target analyte, the excitation modulation frequency, and the detector (lock-in amplifier) phas...
متن کاملDetermination of oxolinic acid in cow's milk and human urine by means of a single-use phosphorimetric sensor.
A single-use phosphorimetric drop plane sensor for the determination of oxolinic acid (OXA) is proposed. The sensor was formed by a 30x16 mm(2) rectangular strip of Mylar type polyester as solid support that contained a circular sensing zone, 6 mm in diameter and 20 mum in thickness, formed by PVC plasticized with tributylphosphate adhered to its surface. When the strip was introduced for 1 hou...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 74 9 شماره
صفحات -
تاریخ انتشار 2002