Finite Element Analysis of Mobile-bearing Unicompartmental Knee Arthroplasty: The Influence of Tibial Component Coronal Alignment.

نویسندگان

  • Guang-Duo Zhu
  • Wan-Shou Guo
  • Qi-Dong Zhang
  • Zhao-Hui Liu
  • Li-Ming Cheng
چکیده

BACKGROUND Controversies about the rational positioning of the tibial component in unicompartmental knee arthroplasty (UKA) still exist. Previous finite element (FE) studies were rare, and the results varied. This FE study aimed to analyze the influence of the tibial component coronal alignment on knee biomechanics in mobile-bearing UKA and find a ration range of inclination angles. METHODS A three-dimensional FE model of the intact knee was constructed from image data of one normal subject. A 1000 N compressive load was applied to the intact knee model for validating. Then a set of eleven UKA FE models was developed with the coronal inclination angles of the tibial tray ranging from 10° valgus to 10° varus. Tibial bone stresses and strains, contact pressures and load distribution in all UKA models were calculated and analyzed under the unified loading and boundary conditions. RESULTS Load distribution, contact pressures, and contact areas in intact knee model were validated. In UKA models, von Mises stress and compressive strain at proximal medial cortical bone increased significantly as the tibial tray was in valgus inclination >4°, which may increase the risk of residual pain. Compressive strains at tibial keel slot were above the high threshold with varus inclination >4°, which may result in greater risk of component migration. Tibial bone resection corner acted as a strain-raiser regardless of the inclination angles. Compressive strains at the resected surface slightly changed with the varying inclinations and were not supposed to induce bone resorption and component loosening. Contact pressures and load percentage in lateral compartment increased with the more varus inclination, which may lead to osteoarthritis progression. CONCLUSIONS Static knee biomechanics after UKA can be greatly affected by tibial component coronal alignment. A range from 4° valgus to 4° varus inclination of tibial component can be recommended in mobile-bearing UKA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Lower Limb Alignment and Tibial Component Inclination on the Biomechanics of Lateral Compartment in Unicompartmental Knee Arthroplasty

BACKGROUND Lateral compartmental osteoarthritis (LCOA), a major complication after medial mobile-bearing unicompartmental knee arthroplasty (UKA), is highly associated with the increased stress of the lateral compartment. This study aimed to analyze the effects on the stress and load distribution of the lateral compartment induced by lower limb alignment and coronal inclination of the tibial co...

متن کامل

Evaluation of implant position and knee alignment after patient-specific unicompartmental knee arthroplasty.

Implant positioning and knee alignment are two primary goals of successful unicompartmental knee arthroplasty. This prospective study outlines the radiographic results following 32 patient-specific unicompartmental medial resurfacing knee arthroplasties. By means of standardized pre- and postoperative radiographs of the knee in strictly AP and lateral view, AP weight bearing long leg images as ...

متن کامل

Early Results of Oxford Mobile Bearing Medial Unicompartmental Knee Replacement (UKR) with the Microplasty Instrumentation: An Indian Experience

Background: Oxford medial unicompartmental knee replacement (UKR) is indicated in patients with anteromedialosteoarthritis (AMOA) of the knee. Microplasty (MP) instrumentation was introduced in 2012 as an improvement overphase 3 instrumentation. Advantages of this instrumentation include conservative tibial cut, decreased tibial re-cut rateand improved component alignment. We report the results...

متن کامل

Unicompartmental Knee Osteoarthritis (UKOA): Unicompartmental Knee Arthroplasty (UKA) or High Tibial Osteotomy (HTO)?

  Background: The aim of this review article is to analyze the results of high tibial osteotomy compared to unicompartmental knee arthroplasty in patients with unicompartmental knee osteoarthritis.   Methods: The search engine used was PubMed. The keywords were: "high tibial osteotomy versus unicompartmental knee arthroplasty". Twenty-one articles were found on 28 February 2015, but only eighte...

متن کامل

Effect of Polyethylene Crosslinking and Bearing Design on Wear of Unicompartmental Arthroplasty.

Wear and polyethylene damage continue to be important factors affecting outcomes of unicompartmental knee arthroplasty. We compared two design rationales for unicompartmental arthroplasty: fully congruent mobile bearings; or moderately conforming fixed bearings using experimental and computational wear simulation. Experimental wear rates were 3.89 (±0.12) mg/million cycles for the highly crossl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chinese medical journal

دوره 128 21  شماره 

صفحات  -

تاریخ انتشار 2015