Characterisation of a Vitrocell® VC 10 in vitro smoke exposure system using dose tools and biological analysis

نویسندگان

  • David Thorne
  • Joanne Kilford
  • Rebecca Payne
  • Jason Adamson
  • Ken Scott
  • Annette Dalrymple
  • Clive Meredith
  • Deborah Dillon
چکیده

BACKGROUND The development of whole smoke exposure systems have been driven by the fact that traditional smoke exposure techniques are based on the particulate phase of tobacco smoke and not the complete smoke aerosol. To overcome these challenges in this study, we used a Vitrocell® VC 10 whole smoke exposure system. For characterisation purposes, we determined smoke deposition in relationship to airflow (L/min), regional smoke deposition within the linear exposure module, vapour phase dilution using a known smoke marker (carbon monoxide) and finally assessed biological responses using two independent biological systems, the Ames and Neutral Red uptake (NRU) assay. RESULTS Smoke dilution correlates with particulate deposition (R2 = 0.97) and CO concentration (R2 = 0.98). Regional deposition analysis within the linear exposure chamber showed no statistical difference in deposited mass across the chamber at any airflows tested. Biological analysis showed consistent responses and positive correlations with deposited mass for both the Ames (R2 = 0.76) and NRU (R2 = 0.84) assays. CONCLUSIONS We conclude that in our study, under the experimental conditions tested, the VC 10 can produce stable tobacco smoke dilutions, as demonstrated by particulate deposition, measured vapour phase smoke marker delivery and biological responses from two independent in vitro test systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of cigarette smoke particle deposition within the Vitrocell® exposure module using quartz crystal microbalances

BACKGROUND Cigarette smoking is a cause of a variety of serious diseases, and to understand the toxicological impact of tobacco smoke in vitro, whole smoke exposure systems can be used. One of the main challenges of the different whole smoke exposure systems that are commercially available is that they dilute and deliver smoke in different ways, limiting/restricting the cross-comparison of biol...

متن کامل

Characterization of the Vitrocell® 24/48 in vitro aerosol exposure system using mainstream cigarette smoke

BACKGROUND Only a few exposure systems are presently available that enable cigarette smoke exposure of living cells at the air-liquid interface, of which one of the most versatile is the Vitrocell® system (Vitrocell® Systems GmbH). To assess its performance and optimize the exposure conditions, we characterized a Vitrocell® 24/48 system connected to a 30-port carousel smoking machine. The Vitro...

متن کامل

A comparative assessment of cigarette smoke aerosols using an in vitro air–liquid interface cytotoxicity test

This study describes the evaluation of a modified air-liquid interface BALB/c 3T3 cytotoxicity method for the assessment of smoke aerosols in vitro. The functionality and applicability of this modified protocol was assessed by comparing the cytotoxicity profiles from eight different cigarettes. Three reference cigarettes, 1R5F, 3R4F and CORESTA Monitor 7 were used to put the data into perspecti...

متن کامل

The comparative in vitro assessment of e-cigarette and cigarette smoke aerosols using the γH2AX assay and applied dose measurements.

DNA damage can be caused by a variety of external and internal factors and together with cellular responses, can establish genomic instability through multiple pathways. DNA damage therefore, is considered to play an important role in the aetiology and early stages of carcinogenesis. The DNA-damage inducing potential of tobacco smoke aerosols in vitro has been extensively investigated; however,...

متن کامل

The assessment of H2AX induction from conventional and electronic cigarette aerosols

Exposure systems have been used to assess cigarette smoke aerosols for many years, using a variety of invitro endpoints. These systems produce a more physiologically relevant test matrix compared to traditionalmethods, and as a result in vitro aerosol techniques are widely being developed. Of particular interest aregenotoxicity assays such as the H2AX assay which may be used to dete...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2013