Optimization of Digital Mammography Resolution Using Magnification Technique in Computed Radiography

نویسندگان

  • Gham Hur
  • Yoon Joon Hwang
  • Soon Joo Cha
  • Yong Hoon Kim
چکیده

Purpose: To determine whether magnified digital mammography using a computed radiography system can produce better spatial resolution by reducing the focus-object distance, and to define the optimal magnification factor when a large x-ray tube focal spot is used for digital mammography using a CR system. Materials and Methods: Digital images obtained using computed radiography of a breast phantom were obtained using various magnification factors. Up to twelve acrylic blocks each measuring one centimeter in height were used to increase the distance between the breast phantom and the base plate (screen holder), in order to create the magnification images. The large (0.3 mm) focal spot of the x-ray tube was used for the entire series of images. Three radiologists participated in the evaluation of the images, in order to determine which had the best resolution. The resolving ability of the line pair structures and image clarity of the detectable artificial microcalcifications (specs) were the two factors used to determine the resolution of the images. The images were not compressed aFnd the viewing conditions, including the magnification factors, brightness and contrast, were fixed. The images were displayed on four high resolution PACS dedicated monitors (5 mega pixel LCD, BARCO Belgium). Results: A focus-object distance of 590 mm and a source-to-image receptor distance of 650 mm (set by the manufacturer) resulted in the best resolution, when combined with a magnification factor of 1.1. All three radiologists agreed on this result. Two of the radiologists believed that at least two more line pairs were better separated on the magnified image having the best resolution than on the unmagnified image, while one radiologist believed that three more line pairs were better separated on this magnified image. Using images with still larger magnification factors did not improve the resolution due to edge blurring. It was easier to determine the resolving power by means of the line-pair structures than by assessing the clarity of the artificial microcalcifications

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing the Accuracy of Cone Beam Computed Tomography,Digital Intraoral Radiography and Conventional Intraoral Radiography in the Measurement of Periodontal Bone Defects

Background and Aim: Cone beam computed tomography (CBCT) produces high-quality data in periodontal diagnosis and treatment planning. The aim of this study was to compare the accuracy of CBCT with intraoral digital and conventional radiography in the measurement of periodontal bone defects.  Methods and Materials: In this diagnostic research, two hundred and eighteen artificial osseous d...

متن کامل

Optimization of Dose and Image Quality in Full-fiand Computed Radiography Systems for Common Digital Radiographic Examinations

IntroductionA fine balance of image quality and radiation dose can be achieved by optimization to minimize stochastic and deterministic effects. This study aimed in ensuring that images of acceptable quality for common radiographic examinations in digital imaging were produced without causing harmful effects. Materials and MethodsThe study was conducted in three phases. The pre-optimization inv...

متن کامل

Evaluation of Image Magnification in Digital Panoramic Radiography

Introdouction: The aim of the present study was to investigate image magnification in digital panoramic radiography and assess the effect of anatomical sites on the magnification in both males and females. Materials and methods: In this retrospective study, digital panoramic radiographs of 48 patients with 202 implants were investigated. Implant diameter and length were measured on pan...

متن کامل

Characterization and Optimization of Silicon-strip Detectors for Mammography and Computed Tomography

The goal in medical x-ray imaging is to obtain the image quality required for a given detection task, while ensuring that the patient dose is kept as low as reasonably achievable. The two most common strategies for dose reduction are: optimizing incident x-ray beams and utilizing energy information of transmitted beams with new detector techniques (spectral imaging). In this thesis, dose optimi...

متن کامل

Quality comparison of direct digital panoramic radiography and computed radiography panoramic

BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels). The first category is defined as computed radiography (CR) or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR). Both of these technologies have their o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004