Adaptive Control of the Active Power of an Electric Arc Furnace

نویسندگان

  • MANUELA PANOIU
  • CAIUS PANOIU
  • IOAN SORA
  • ANCA IORDAN
چکیده

The electric arc furnaces are a very large power load, determining the negative effects on the power quality (harmonics currents, unbalanced load, and reactive power). For a maximum efficiency of the power consumption it is necessary to use an automat system of electrodes position control, in order to obtain a high value of power factor and a maximum efficiency. In this paper is present an adaptive method for process control for an Electric Arc Furnace. The method was validate using simulation. Key-Words: Adaptive control, LMS algorithm, active power control

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The New Definitions for the Power Terms in Distorted and Unbalanced Conditions and Calculation of these Terms for an Electric Arc Furnace

The rapid increase of non-linear loads in the last three decades has caused electrical quantities such as voltages and currents in 3-phase distribution systems to become distorted waveforms. This paper reviews, explains and discusses some new concepts, definitions and new available theory in the unbalanced and distorted systems. The usefulness of the proposed practical definitions is investigat...

متن کامل

The New Definitions for the Power Terms in Distorted and Unbalanced Conditions and Calculation of these Terms for an Electric Arc Furnace

The rapid increase of non-linear loads in the last three decades has caused electrical quantities such as voltages and currents in 3-phase distribution systems to become distorted waveforms. This paper reviews, explains and discusses some new concepts, definitions and new available theory in the unbalanced and distorted systems. The usefulness of the proposed practical definitions is investigat...

متن کامل

Study about the Process Control of an Electric Arc Furnace using Simulations based on an Adaptive Algorithm

The electric arc furnaces are a very large power load, determining the negative effects on the power quality (harmonics currents, unbalanced load, and reactive power). For a maximum efficiency of the power consumption it is necessary to use an automat system for control the harmonics filters, the reactive power compensation installation and the electrodes position, in order to obtain a high val...

متن کامل

A Probabilistic Three-Phase Time Domain Electric Arc Furnace Model based on analytical method

An electric arc furnace (EAF) is known as nonlinear and time variant load that causes power quality (PQ) problems such as, current, voltage and current harmonics, voltage flicker, frequency changes in power system. One of the most important problems to study the EAF behavior is the choice of a suitable model for this load. Hence, in this paper, a probabilistic three-phase model is proposed base...

متن کامل

Path Planning and Control of an Industrial Robot Used for Opening Tap Hole of an Electric Arc Furnace

The electric arc furnace (EAF) is one of the popular methods of steel production from steel scraps. The plasma arc is used in EAF to generate heat for melting scarp or direct reduced iron (DRI). The liquid metal is drained from the EAF through the tap hole. Nowadays, it is critical to use Automated/robotic tools for opening the tap hole with oxygen lancing. Because many workers have been blinde...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008