Commissioning of Varian ring & tandem HDR applicators: reproducibility and interobserver variability of dwell position offsets

نویسندگان

  • Ryan McMahon
  • Tingliang Zhuang
  • Beverly A. Steffey
  • Haijun Song
  • Oana I. Craciunescu
چکیده

Studies have shown that source dwells within Varian's HDR CT/MR compatible ring applicators can deviate from intended positions by several millimeters. Quantifying this offset is an important part of commissioning. The aims of this study were to: 1) determine the reproducibility of the offset, 2) study the interobserver variation in the offset's measurement, and 3) quantify the dosimetric impact of the offset. Offsets were measured for four ring applicators: two 30°, one 45°, and one 60°. Dwell positions were measured five times for each ring to determine the reproducibility of source positioning. Experiments were done to compare two separate source wires, as well as different time points within a single source wire's lifecycle. Data were analyzed by three independent observers. To quantify the dosimetric impact of the offset, a treatment plan was generated using BrachyVision. The dose to point A, and the D(2cc) metric for rectum and bladder were calculated with and without the offset. For the 45° and 60° rings, measured offsets were 3.0 mm and 3.6 mm, respectively. The 30° ring showed substantial variation in distal dwell positions (maximum difference between the five experiments of 2.9 mm). Subsequent testing of a replacement ring showed an offset of 2.4 mm that was more reproducible. Offsets varied less than 1 mm between different source wires, and changed less than 1 mm over the course of a source wire's lifecycle. When comparing observers, the average range in a measurement of a dwell position was 0. 5 mm (σ = 0.2 mm, max 1.3 mm). The offset resulted in dose variations to point A, bladder, and rectum of less than 1%, 2%, and 5%, respectively. Results indicate that Varian rings can show systematic and random offsets of more than 3 mm. Some can be considered defective and should be replaced. Each applicator should be individually commissioned and reproducibility should be confirmed with multiple tests.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new approach to measure dwell position inaccuracy in HDR ring applicators – quantification and corrective QA

As part of quality assurance (QA) in high dose rate brachytherapy, it is necessary to verify that the source dwell positions correspond to the radiographic markers used in simulation and treatment planning. The procedure is well established for linear tandem applicators. However, with the advent of ring applicators, this has become more critical and challenging. This work describes a new approa...

متن کامل

Dwell position inaccuracy in the Varian GammaMed HDR ring applicator

Varian has issued two Product Notification Letters warning of known inaccuracies in dwell positions for their GammaMed HDR ring applicator. This inaccuracy was measured for two sets of applicators. Autoexposed radiographs were taken of the HDR source at different dwell positions and analyzed per Varian recommendations using tools within the BrachyVision treatment planning program. Comparison be...

متن کامل

Quality assurance measurements for high‐dose‐rate brachytherapy without film

The purpose of this study was to develop new and modified tools that allow HDR brachytherapy quality assurance tests to be carried out efficiently without film, video cameras, stopwatches, and mechanical rulers; and to devise methods that use these new tools for daily and quarterly check procedures, which are efficient and provide increased accuracy compared to previous methods. The HDR brachyt...

متن کامل

SU-E-T-138: Quantification of Dwell Position Inaccuracy in Varian GammaMed HDR Titanium Ring Applicators.

PURPOSE To quantify the dwell position inaccuracy in Titanium ring applicators and develop a test to be performed quarterly, after source exchange. METHODS All three rings from our Titanium kit (30, 45, 60 deg.) were used for this study. EDR2 film was placed on the Simulator table and a ring was taped to the film, with a solid water slab as buildup. A 1-cm spacing dummy wire was inserted into...

متن کامل

The variability of applicator position among high dose rate intracavitary brachytherapy applications in cervical cancer patients treated with ring & tandem applicators.

OBJECTIVE To evaluate the interindividual and intraindividual applicator position variability in high dose rate ring and tandem intracavitary brachytherapy applications in locally advanced cervical cancer. PATIENTS AND METHODS Eight patients with locally advanced cervical cancer formed the study population. They had been treated in Dokuz Eylül University Department of Radiation Oncology betwe...