An Investigation on Electric Field Distribution around 380 kV Transmission Line for Various Pylon Models
نویسنده
چکیده
In this study, electric field distribution analyses for three pylon models are carried out by a Finite Element Method (FEM) based software. Analyses are performed in both stationary and time domains to observe instantaneous values along with the effective ones. Considering the results of the study, different line geometries is considerably affecting the magnitude and distribution of electric field although the line voltages are the same. Furthermore, it is observed that maximum values of instantaneous electric field obtained in time domain analysis are quite higher than the effective ones in stationary mode. In consequence, electric field distribution analyses should be individually made for each different line model and the limit exposure values or distances to residential buildings should be defined according to the results obtained. Keywords—Electric field, energy transmission line, finite element method, pylon.
منابع مشابه
Effects of Disc Insulator Type and Corona Ring on Electric Field and Voltage Distribution over 230-kV Insulator String by Numerical Method
Insulator strings with several material and profiles are very common in overhead transmission lines. However, the electric field and voltage distribution of insulator string is uneven which may easily lead to corona, insulators’ surface deterioration and even flashover. So the calculation of the electric field and voltage distribution along them is a very important factor in the operation time....
متن کاملFinite Element Approach to Electric Field Distribution Resulting from Phase-sequence Orientation of a Double- Circuit High Voltage Transmission Line
This paper proposes a mathematical model of electric fields caused by high voltage conductors of electric power transmission systems by using a set of second-order partial differential equations. This study has considered the effect of conductor phase-sequence orientation on electric fields emitted around a doublecircuit, extra high-voltage, power transmission line. Six typical-used phase-seque...
متن کاملElectromagnetic Field Distribution of Phase-sequence Orientation of a Double-Circuit Power Transmission Line Based on Finite Element Method
This paper proposes a mathematical model of electric and magnetic fields caused by high voltage conductors of electric power transmission systems by using a set of second-order partial differential equations. This study has considered the effect of conductor phase-sequence orientation on electromagnetic fields emitted around a double-circuit, extra high-voltage, power transmission line. Five ty...
متن کاملAn Investigation into Magnetic Field Management under Power Transmission Lines using Delta Configurations
The increase of power demand has increased the need for transmitting huge amount of power over long distances. Large transmission lines configurations with high voltage and current levels generate large values of electric and magnetic fields stresses which affect the humanbeing and the nearby objects located at ground surfaces. This has in turn prompted increased activity in the documentation o...
متن کاملAssessment of Electric Field Distribution Inside 500/220 kV Open Distribution Substations during Working Conditions
Received Mar 2, 2014 Revised Jul 10, 2014 Accepted Jul 23, 2014 The high level electric field intensity produced by high voltage (HV) equipments inside 500/220 kV substations is harmful for the human (staff) health. Therefore the minimum health and safety requirements regarding the exposure of workers to the risk arising from electric fields produced inside these substations is still considered...
متن کامل