Bonding Durability of Four Adhesive Systems.

نویسندگان

  • Leila Atash Biz Yeganeh
  • Elaheh Seyed Tabai
  • Mahshid Mohammadi Basir
چکیده

OBJECTIVES This study aimed to compare the durability of four adhesive systems by assessing their microtensile bond strength (MTBS) and microleakage during six months of water storage. MATERIALS AND METHODS A total of 128 human third molars were used. The adhesives tested were Scotch Bond Multipurpose (SBMP), Single Bond (SB), Clearfil-SE bond (CSEB), and All-Bond SE (ABSE). After sample preparation for MTBS testing, the microspecimens were subjected to microtensile tester after one day and six months of water storage. For microleakage evaluation, facial and lingual class V cavities were prepared and restored with composite. After thermocycling, microleakage was evaluated. Bond strength values were subjected to one-way ANOVA and Tamhane's test, and the microleakage data were analyzed by the Kruskal-Wallis, Dunn, Mann Whitney and Wilcoxon tests (P<0.05). RESULTS Single Bond yielded the highest and ABSE yielded the lowest bond strength at one day and six months. Short-term bond strength of SBMP and CSEB was similar. After six months, a significant decrease in bond strength was observed in ABSE and SBMP groups. At one day, ABSE showed the highest microleakage at the occlusal margin; however, at the gingival margin, there was no significant difference among groups. Long-term microleakage of all groups at the occlusal margins was similar, whilst gingival margins of SBMP and SB showed significantly higher microleakage. CONCLUSION The highest MTBS and favorable sealability were obtained by Clearfil SE bond. Water storage had no effect on microleakage of self-etch adhesives at the gingival margin or MTBS of CSEB and SB.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative comparison of permeability in the adhesive interface of four adhesive systems

Since the acid-etch technique for bonding to the tooth substrate had been introduced, adhesive dentistry evolved rapidly due to two main reasons; esthetic satisfaction and minimal invasiveness. Some retrospective clinical studies have showed the favorable durability of resin restoration over 10 years. However, the majority of bonded restorations are disadvantaged by their early failure during s...

متن کامل

Effect of Chlorhexidine on Micro-Shear Bond Strength of Two Adhesive Systems After Aging

Background and Aim: Recurrent caries and low bond strength are the main causes of composite restorations failure. This study sought to assess the effect of chlorhexidine (CHX) on micro-shear bond strength (MSBS) to dentin of a fourth generation adhesive system and a universal bonding agent after aging. Materials and Methods: This in vitro study used 32 extracted third molars and 3-5mm thick de...

متن کامل

Durability of Composites and Adhesive Bonds

Any consideration of the durability of the high performance composite materials and structural adhesives used in aerospace construction must recognize that these are brittle materials and that their failure mode is characterized by flaw growth and propagation. One can easily anticipate a variety of flaws and defects; surface cuts, internal cracks due to stress relief and deliberate holes cut fo...

متن کامل

Effect of simplified ethanol-wet bonding on dentin bonding durability of etchand-rinse adhesives.

This in vitro study evaluated the effects of simplified ethanol-wet bonding technique on dentin bonding durability of two etchand-rinse adhesives to bovine dentin. Sixteen freshly extracted bovine incisors were divided into four groups according to bonding technique (water-wet or ethanol-wet bonding) and adhesive (Single Bond 2 or Prime & Bond NT). After etching and rinsing, dentin surfaces wer...

متن کامل

Adhesives for Achieving Durable Bonds with Acetylated Wood

Acetylation of wood imparts moisture durability, decay resistance, and dimensional stability to wood; however, making durable adhesive bonds with acetylated wood can be more difficult than with unmodified wood. The usual explanation is that the acetylated surface has fewer hydroxyl groups, resulting in a harder-to-wet surface and in fewer hydrogen bonds between wood and adhesive. This concept w...

متن کامل

Effects of Type I Collagen Degradation on the Durability of Three Adhesive Systems in the Early Phase of Dentin Bonding

OBJECTIVE This study was designed to evaluate the effects of type I collagen degradation on the durability of three adhesive systems in the early phase of dentin bonding. METHODS Bonded dentin specimens were prepared using three different types of adhesive systems. Micro-tensile bond strength and degradation of collagen were tested before, and after 1 month or 4 months of aging in artificial ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of dentistry

دوره 12 8  شماره 

صفحات  -

تاریخ انتشار 2015