Results of application of external fixation with different types of fixators.
نویسندگان
چکیده
INTRODUCTION Extra-focal or external fixation is the method of fracture fixation through the healthy part of the bone using pins or wires. OBJECTIVE The aim was to determine which external splints (Ortofix, Mitković, Charnley and Ilizarov) had the best biomechanical properties in primary stabilization of spiral, transverse and commutative bone fractures. METHODS To determine the investigation methodology of biomechanical characteristics of the external fixator we used mathematical and computer simulator (software), juvidur physical model and clinical examination. RESULTS Values of advancing fragments in millimetres obtained by the study of mathematical and computer simulator (software): Charnley--0.080 mm, Mitković M 20--0.785 mm, Ilizarov--2.245 mm and Ortofix--1.400 mm. In testing thejuvidur model the following values were obtained: the external fixator Mitković M20--1.380 mm, Ortofix--1.470 mm, Ilizarov--2.410 mm, and Charnley--2.510 mm. Clinical research of biomechanical characteristics of the effect of vertical force yielded the following results: Mitković M20--0.89 mm, Ortofix--0.14 mm, Charnley--0.80 mm and Ilizarov--1.23 mm. CONCLUSION When determining the total number of the stability test splints under the effect of vertical force (compression) and force effect in antero-posterior, later-lateral plane of cross, spiral and comminuted long bone fractures, the best unified biomechanical stability was shown bythe following external fixators: firstly, Mitković M20 (0.93mm), secondly, Charnley fixator (1.14 mm), thirdly, Ortofix (1.22 mm), and fourthly, Ilizarov (1.60 mm).
منابع مشابه
JC Clasper, SL Phillips. Early Failure Of External Fixation In The Management Of War Injuries
Objective To review external fixation in the management of war injuries. Method We prospectively followed up 15 external fixators (14 patients) applied in the management of war injuries. All these patients were treated at 202 Field Hospital during the 2003 Gulf Conflict. Results Of the 15 fixators, 13 (86.7%) required early revision or removal due to complications of the injury or the fixator. ...
متن کاملJC Clasper, SL Phillips. Early Failure Of External Fixation In The Management Of War Injuries
Objective To review external fixation in the management of war injuries. Method We prospectively followed up 15 external fixators (14 patients) applied in the management of war injuries. All these patients were treated at 202 Field Hospital during the 2003 Gulf Conflict. Results Of the 15 fixators, 13 (86.7%) required early revision or removal due to complications of the injury or the fixator. ...
متن کاملEarly failure of external fixation in the management of war injuries.
OBJECTIVE To review external fixation in the management of war injuries. METHOD We prospectively followed up 15 external fixators (14 patients) applied in the management of war injuries. All these patients were treated at 202 Field Hospital during the 2003 Gulf Conflict. RESULTS Of the 15 fixators, 13 (86.7%) required early revision or removal due to complications of the injury or the fixat...
متن کاملLCP external fixation - External application of an internal fixator: two cases and a review of the literature
The locking compression plate (LCP) is an angle-stable fixator intended for intracorporeal application. In selected cases, it can be applied externally in an extracorporeal location to function as a monolateral external fixator. We describe one patient with Schatzker V tibial plateau fracture and one patient with Gustillo IIIB open tibia shaft fracture treated initially with traditional externa...
متن کاملA more patient-friendly use of circular fixators in deformity correction
Purpose The evaluation of a construction that allows the exchange of circular and unilateral external fixators on the same fixation pins to the bone in outpatient circumstances during bone lengthening and alignment procedures. Methods Nine children were treated with this concept. After bone lengthening and alignment, the circular fixators were exchanged for unilateral fixators in the outpatient...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Srpski arhiv za celokupno lekarstvo
دوره 140 5-6 شماره
صفحات -
تاریخ انتشار 2012