Effect of valve design on the stent internal diameter of a bioprosthetic valve: a concept of true internal diameter and its implications for the valve-in-valve procedure.
نویسندگان
چکیده
The goal of this study was to provide a measurement of the true internal diameter (ID) of various surgical heart valves (SHV) to facilitate the valve-in-valve (VIV) procedure. During a VIV procedure, it is important to choose the right of the transcatheter heart valve (THV). Most users use the stent ID of an SHV to select the appropriate THV size. Echocardiography and computed tomography measurements are not yet standardized for measuring the ID of a variety of SHVs. Hence, we measured the true ID of SHV to assess the effect of valve design on the stent ID. Thirteen types of stented and 3 types of stentless valves were evaluated. True ID measurements were obtained using calipers and Hegar dilators. These were compared with the stent ID measurements. Fluoroscopy was used to confirm the impact of SHV designs on the true ID. Caliper measurements were found to be inaccurate and are hence not recommended. Hegar dilator measurements revealed a trend of reduction in stent ID. Porcine valves were most affected by their design, with reduction in the stent ID by at least 2 mm; pericardial valves with leaflets sutured inside the stent had the stent ID reduced by at least 1 mm, and SHV with leaflets sutured outside the stent had no effect on stent ID. In the majority of SHV designs, there is a reduction in the stent ID as a result of leaflet tissue. This is important in borderline sizes to avoid problems associated with oversizing and also to confirm suitability for the VIV procedure in the smaller label sizes of SHV.
منابع مشابه
Trans-catheter Bioprosthetic Heart Valve Implantation in Iran (Tehran Heart Centre Experience)
Introduction: With the development of interventional cardiology in the world, in addition to coronary and aortic diseases, the treatment of heart valve diseases through catheters has recently begun. The treatment of aortic stenosis (which was only possible with open surgery and valve replacement) was first performed in the world in 2002 by Alain Cribier in France with catheter insertion of the ...
متن کاملEffect of Contact Pressure and Frequency on Contact Heat Transfer Between Exhaust Valve and its Seat
The hot gases produced by the internal combustion engines passes through the exhaust valve and causes high temperatures in the exhaust valve and its seat. To avoid damaging the exhaust valve, heat must be transferred from the valve to its seat during the contact they make at the opening and closing cycle. Heat transfer rate from the exhaust valve to its seat is a function of many factors. One o...
متن کاملRupture of chorda tendineae of the tricuspid valve in a horse: a case report
A2-year-old cachectic cross-breed gelding was admitted toVeterinary Teaching Hospital of University of Tehran followingthe onset of a marked respiratory distress, coughing and ventraledema. Clinical examinations indicated harsh respiratory andexpiratory sounds as well as jugular vein distention. Therespiratory and heart rates were 35/min and 60 bpm, respectively.Agrade III/IV pansystolic murmur...
متن کاملTranscatheter Aortic Valve Replacement: A Review Article
Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...
متن کاملNumerical Simulation of the Effect of Valve Opening and Particle Concentration on the Erosion Damage in Ball Valves of Pressure Reducing Station
Ball valve is one of valves that have many applications in industry especially in gas delivery systems. This kind of valve is categorized in the on- off flow control valve. This study aims to investigate unusual application of ball valve to control fluid flow in the oil and gas industry and its destructive effect including erosion of ball and body of valve. Simulation of industrial ball valve i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- JACC. Cardiovascular interventions
دوره 7 2 شماره
صفحات -
تاریخ انتشار 2014