Circulating microRNAs for predicting and monitoring response to mechanical circulatory support from a left ventricular assist device
نویسندگان
چکیده
AIMS There are few non-invasive techniques to predict and monitor patients' responses to left ventricular assist device (LVAD) therapy. MicroRNAs (miRs) are small non-coding RNAs with intricate roles in cardiovascular disease. They are stable in the circulation, readily quantified, and may be useful as new biomarkers. This study sought to identify candidate miR biomarkers for further investigation. METHODS AND RESULTS We studied 53 plasma and 20 myocardial samples from 19 patients who underwent HeartMate II LVAD implantation, and used a screening microarray to analyse the change in expression of 1113 miRs after 6 months LVAD support. Twelve miRs showed significant variation and underwent validation, yielding miR-1202 and miR-483-3p as candidate biomarkers. In the test cohort, circulating miR-483-3p showed early and sustained up-regulation with LVAD support, with median (interquartile range) fold changes from baseline of 2.17 (1.43-2.62; P = 0.011), 2.27 (1.12-2.42; P = 0.036), 1.87 (1.64-4.36; P = 0.028), and 2.82 (0.70-10.62; P = 0.249) at 3, 6, 9, and 12 months, respectively, whilst baseline plasma miR-1202 identified good vs. poor LVAD responders [absolute expression 1.296 (1.293-1.306) vs. 1.311 (1.310-1.318) arbitrary units; P = 0.004]. Both miRs are enriched in ventricular myocardium, suggesting the heart as the possible source of the plasma fraction. CONCLUSIONS This is the first report of circulating miR biomarkers in LVAD patients. We demonstrate the feasibility of this approach, report the potential for miR-483-3p and miR-1202, respectively, to monitor and predict response to LVAD therapy, and propose further work to study these hypotheses and elucidate roles for miR-483-3p and miR-1202 in clinical practice and in underlying biological processes.
منابع مشابه
Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...
متن کاملApplication of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)
Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...
متن کاملAdvanced mechanical circulatory support with the HeartMate left ventricular assist device in the year 2000.
This paper describes the HeartMate left ventricular assist device (ThermoCardiosystems Inc, Woburn, MA) technology, which has been successfully introduced into the clinical arena with more than 2,400 implants as of the year 2000. The review summarizes the clinical experience, and identifies the benefits and limitations of the current state-of-the-art technology of the leading implantable circul...
متن کاملSurgical Treatment of Advanced Heart Failure- Left Ventricular Assist Device Implantation and Adjuvant Tricuspid Valve Repair
Cardiac transplantation is the treatment of choice in patients with end-stage heart failure. Insufficient number of donors in all health systems resulted in the need for intensive development of devices for mechanical circulatory support. Right ventricular failure (RVF) combined with major tricuspid insufficiency among the group of patients who are candidates for the left ventricular assist dev...
متن کاملPrediction of hemodynamics under left ventricular assist device.
Left ventricular assist device (LVAD) saves lives in patients with severe left ventricular (LV) failure. However, predicting how much LVAD boosts total cardiac output (CO) remains difficult. This study aimed to develop a framework to quantitatively predict the impact of LVAD on hemodynamics. We adopted the circulatory equilibrium framework and incorporated LVAD into the integrated CO curve to d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 16 شماره
صفحات -
تاریخ انتشار 2014