Desflurane consumption during automated closed-circuit delivery is higher than when a conventional anesthesia machine is used with a simple vaporizer-O2-N2O fresh gas flow sequence

نویسندگان

  • Sofie De Cooman
  • Nathalie De Mey
  • Bram BC Dewulf
  • Rik Carette
  • Thierry Deloof
  • Maurice Sosnowski
  • Andre M De Wolf
  • Jan FA Hendrickx
چکیده

BACKGROUND The Zeus® (Dräger, Lübeck, Germany), an automated closed-circuit anesthesia machine, uses high fresh gas flows (FGF) to wash-in the circuit and the lungs, and intermittently flushes the system to remove unwanted N₂. We hypothesized this could increase desflurane consumption to such an extent that agent consumption might become higher than with a conventional anesthesia machine (Anesthesia Delivery Unit [ADU®], GE, Helsinki, Finland) used with a previously derived desflurane-O₂-N₂O administration schedule that allows early FGF reduction. METHODS Thirty-four ASA PS I or II patients undergoing plastic, urologic, or gynecologic surgery received desflurane in O₂/N₂O. In the ADU group (n = 24), an initial 3 min high FGF of O₂ and N₂O (2 and 4 L.min-1, respectively) was used, followed by 0.3 L.min-1 O2 + 0.4 L.min-1 N₂O. The desflurane vaporizer setting (FD) was 6.5% for the first 15 min, and 5.5% during the next 25 min. In the Zeus group (n = 10), the Zeus® was used in automated closed circuit anesthesia mode with a selected end-expired (FA) desflurane target of 4.6%, and O₂/N₂O as the carrier gases with a target inspired O₂% of 30%. Desflurane FA and consumption during the first 40 min were compared using repeated measures one-way ANOVA. RESULTS Age and weight did not differ between the groups (P > 0.05), but patients in the Zeus group were taller (P = 0.04). In the Zeus group, the desflurane FA was lower during the first 3 min (P < 0.05), identical at 4 min (P > 0.05), and slightly higher after 4 min (P < 0.05). Desflurane consumption was higher in the Zeus group at all times, a difference that persisted after correcting for the small difference in FA between the two groups. CONCLUSION Agent consumption with an automated closed-circuit anesthesia machine is higher than with a conventional anesthesia machine when the latter is used with a specific vaporizer-FGF sequence. Agent consumption during automated delivery might be further reduced by optimizing the algorithm(s) that manages the initial FGF or by tolerating some N₂ in the circuit to minimize the need for intermittent flushing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Severe ADU Desflurane Vaporizing Unit Malfunction

To the Editor:—A 77-yr-old man undergoing insertion of a J-splint for renal obstruction received general anesthesia delivered with an ADU anesthesia machine (Anesthesia Delivery Unit; Datex-Ohmeda, Stockholm, Sweden). A 5% desflurane vaporizer concentration setting with an O2/N2O mixture (2 and 3 l/min, respectively) resulted in stable inspired and expired desflurane concentrations (fig. 1). Im...

متن کامل

Severe ADU desflurane vaporizing unit malfunction.

To the Editor:—A 77-yr-old man undergoing insertion of a J-splint for renal obstruction received general anesthesia delivered with an ADU anesthesia machine (Anesthesia Delivery Unit; Datex-Ohmeda, Stockholm, Sweden). A 5% desflurane vaporizer concentration setting with an O2/N2O mixture (2 and 3 l/min, respectively) resulted in stable inspired and expired desflurane concentrations (fig. 1). Im...

متن کامل

Time course of inhaled anaesthetic drug delivery using a new multifunctional closed-circuit anaesthesia ventilator. In vitro comparison with a classical anaesthesia machine.

BACKGROUND The aim of this study was to detail the time-course, defined as the changes in end-tidal drug concentration with time, and consumption of inhaled anaesthetics when using a multifunctional closed-circuit anaesthesia machine in various drug delivery modes, and to compare it with a classical anaesthesia machine using an out-of-circle vaporizer under high and low fresh gas flow condition...

متن کامل

Global warming potential of inhaled anesthetics: application to clinical use.

BACKGROUND Inhaled anesthetics are recognized greenhouse gases. Calculating their relative impact during common clinical usage will allow comparison to each other and to carbon dioxide emissions in general. METHODS We determined infrared absorption cross-sections for sevoflurane and isoflurane. Twenty-year global warming potential (GWP(20)) values for desflurane, sevoflurane, and isoflurane w...

متن کامل

1-1-12 One-Step Wash-In Scheme for Desflurane-Nitrous Oxide Low-Flow Anesthesia: Rapid and Predictable Induction

BACKGROUND We propose a 1-1-12 wash-in scheme for desflurane-nitrous oxide (N2O) low-flow anesthesia. The objective of our study was to determine the time to achieve alveolar concentration of desflurane (FAD) at 1, 2, 3, 4, 5, and 6%. METHODS We enrolled 106 patients scheduled for elective surgery under general anesthesia. After induction and intubation, wash-in was started with a fresh gas f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC Anesthesiology

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2008