The influence of number of counts in the myocardium in the determination of reproducible functional parameters in gated-SPECT studies simulated with GATE.
نویسندگان
چکیده
UNLABELLED Myocardial perfusion gated-single photon emission computed tomography (gated-SPECT) imaging is used for the combined evaluation of myocardial perfusion and left ventricular (LV) function. The aim of this study is to analyze the influence of counts/pixel and concomitantly the total counts in the myocardium for the calculation of myocardial functional parameters. MATERIAL AND METHODS Gated-SPECT studies were performed using a Monte Carlo GATE simulation package and the NCAT phantom. The simulations of these studies use the radiopharmaceutical (99m)Tc-labeled tracers (250, 350, 450 and 680 MBq) for standard patient types, effectively corresponding to the following activities of myocardium: 3, 4.2, 5.4-8.2 MBq. All studies were simulated using 15 and 30s/projection. The simulated data were reconstructed and processed by quantitative-gated-SPECT software, and the analysis of functional parameters in gated-SPECT images was done by using Bland-Altman test and Mann-Whitney-Wilcoxon test. RESULTS In studies simulated using different times (15 and 30s/projection), it was noted that for the activities for full body: 250 and 350 MBq, there were statistically significant differences in parameters Motility and Thickness. For the left ventricular ejection fractio n (LVEF), end-systolic volume (ESV) it was only for 250 MBq, and 350 MBq in the end-diastolic volume (EDV), while the simulated studies with 450 and 680MBq showed no statistically significant differences for global functional parameters: LVEF, EDV and ESV. CONCLUSION The number of counts/pixel and, concomitantly, the total counts per simulation do not significantly interfere with the determination of gated-SPECT functional parameters, when using the administered average activity of 450 MBq, corresponding to the 5.4 MBq of the myocardium, for standard patient types.
منابع مشابه
Assessment of the integrated role of myocardium perfusion gated SPECT study in patient with parathyroid adenoma by 99mTc-sestamibi
Introduction: The purpose of this study is to assess the integrated role of scintigraphy by Tc99m MIBI in diagnosis of parathyroid adenoma and its impacts on the myocardium, and to evaluate whether myocardium perfusion gated SPECT study could be a complementary routine workup for patient with positive parathyroid adenoma on Tc99m MIBI parathyroid scan. Methods: Rest myocardium perfusion gated ...
متن کاملThe value of the Gated 99mTc-MIBI SPECT in differentiation of fixed myocardial lesions [Persian]
Fixed myocardial defects in both stress and rest images, could be artifactual as a result of soft tissue attenuation. To increase specificity and identify the false positive results, we used gated technique to evaluate the wall motion and wall thickening as an index to differentiate real ischemic lesions from artifactual defects. 93 patients were studied. In 46 patients (48.8%) fixed perf...
متن کاملDiastolic left ventricular functional indices: Comparison between gated myocardial perfusion SPECT and echocardiography
Introduction: Many patients have only diastolic dysfunction without any abnormality in systolic function. We compared cardiac diastolic parameters obtained by gated myocardial perfusion SPECT (Gated SPECT) with those evaluated by echocardiography. Methods: Forty-nine patients (aged 37-85 years, 19 males and 30 women) underwent Gated SPECT and echocardiogr...
متن کاملNormal values of left ventricular functional indices in gated 99mTc-MIBI myocardial perfusion SPECT
Introduction: Although left ventricular(LV) function parameters measured by gated myocardial perfusion SPECT (GSPECT) have been validated, experimental data have revealed that the calculated the LV function parameters using GSPECT are affected by patient populations as well as particular acquisition and processing conditions. We tried to determine the normal values ...
متن کاملDetermination of normal ranges of regional and global phase parameters using gated myocardial perfusion imaging with Cedars-Sinai’s QGS software
Introduction: Myocardial perfusion imaging using gated SPECT and phase analysis is an effective tool in evaluation of mechanical dyssynchrony. The purpose of this study was to determine the normal ranges of global and regional phase parameters. Methods: A total of 100 patients with normal resting and stress electrocardiograms, low pretest likelihood for c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Revista espanola de medicina nuclear e imagen molecular
دوره 34 6 شماره
صفحات -
تاریخ انتشار 2015