New manual and automated method for determining activity of creatine kinase isoenzyme MB, by use of dithiothreitol: clinical applications.
نویسندگان
چکیده
The method is based on the selective activating capacity of dithiothreitol on creatine kinase isoenzyme MB, after isoenzyme MM is activated by glutathione. Isolated isoenzymes MM and MB of human and canine origin were assayed individually and in mixtures of known activities. When glutathione was present in the assay medium the activity of each isoenzyme could be measured individually, but glutathione did not activate isoenzyme MB if it was present in a mixture with MM. Dithiothreitol, added to the serum before assay, activated the isoenzyme MB in the mixture. Values for MB activities obtained for isolated isoenzyme MB and for the isoenzyme mixture after dithiothreitol was added averaged 110 and 111 U/liter, respectively (r = 0.998; y = 1.007 x + 0.298; n = 10). In the serum of 40 patients with documented acute transmural myocardial infarction, the mean proportion of isoenzyme MB activity measured in this way was 5.5% (coefficient of variation, 7.7%). Isoenzyme MB activities measured by use of dithiothreitol compared well with those obtained by conventional electrophoresis/spectrophotometry (r = 0.998; y = 1.09x -0.65) and spectrofluorometry (r = 0.996; y = 1.10 x + 0.80). The assay of MB activity by the dithiothreitol method was automated, by use of an Abbott Bichromatic Analyser and a Calbiochem Super-Stat Pack Kit. In 60 isoenzyme MB determinations the manual and automated method correlated well (r = 0.990; y = 1.0x -1.36). The simplicity of isoenzyme MB determination by use of dithiothreitol and its ease of automation allow routine monitoring of the isoenzyme activity in patients with ischemic heart disease.
منابع مشابه
Development and clinical evaluation of a microcentrifugal analyzer method for determining creatine kinase MB isoenzyme.
We have adapted to a microcentrifugal analyzer an immunoinhibition assay for measuring the activity of creatine kinase MB by using an inhibitory antibody for the M monomer. The method actually measures half the MB activity, but results are not multiplied by two because atypical isoenzymes of creatine kinase, including BB, IgG-BB, and the isoenzyme derived from mitochondria, are also detected, i...
متن کاملUse of creatine kinase MB isoenzyme for diagnosing myocardial infarction when total creatine kinase activity is high.
The usefulness of measuring creatine kinase MB isoenzyme for diagnosing myocardial infarction when activities of total creatine kinase are very high is unclear. We conducted a retrospective study in an urban hospital that serves a largely indigent population. We concentrated on 146 patients whose creatine kinase activity was greater than 1000 U/L (upper limit of normal: 165 U/L for women and 22...
متن کاملA two-tube immunochemical method for determination of CK-MB isoenzyme in serum evaluated.
A new commercial kit (Impres-MB; International Immunoassay Labs.) recently was introduced for measuring the MB isoenzyme of creatine kinase (CK-MB) based on the use of monoclonal antibodies. After antibodies to CK-MM isoenzyme are added to precipitate the CK-MM, antibodies to CK-M monomer are added to precipitate the M-subunit isoenzymes of CK. Subtracting the enzymatic activity of the second s...
متن کاملSemi-automated direct colorimetric measurement of creatine kinase isoenzyme MB activity after extraction from serum by use of a CK-MB-specific monoclonal antibody.
This semi-automated colorimetric assay for the MB isoenzyme of creatine kinase (EC 2.7.3.2) is based on a monoclonal antibody ("Conan-MB") specific for this isoenzyme and is a modification of a previously published method (Vaidya et al., Clin Chem 1986;32:657-63). A 0.64-cm bead coated with 2 to 3 micrograms of antibody is incubated with 100 microL of serum and 10 microL of 0.2 mol/L beta-merca...
متن کاملEffect of the Inhibition of Mitochondrial Creatine Kinase Activity on the Clinical Diagnosis of Suspected Acute Myocardial Infarction
Background: Creatine kinase isoenzyme MB (CK-MB) activity using the immunoinhibition method has been measured in clinical laboratories. However, the presence of mitochondrial CK (MtCK) abnormally increases CK-MB activity when measured using the conventional method, which can lead to misdiagnosis of acute myocardial infarction (AMI). A new CK-MB activity assay kit that can inhibit MtCK activity ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 21 11 شماره
صفحات -
تاریخ انتشار 1975