Agilent PSA Performance Spectrum Analyzer Series
ثبت نشده
چکیده
Its wide dynamic range makes the spectrum analyzer the test instrument of choice for measuring harmonic distortion, intermodulation distortion, adjacent channel power ratio, spurious-free dynamic range, gain compression, etc. Distortion measurements such as these are bounded on one side by the noise floor of the spectrum analyzer and on the other side by the signal power strength at which the spectrum analyzer’s internally generated distortion masks the distortion being measured. The simultaneous low noise floor and low internally generated distortion products uniquely qualify the spectrum analyzer for making distortion measurements.
منابع مشابه
Basic Performance of the Agilent 7700s ICP-MS for the Analysis of Semiconductor Samples
Agilent ICP-MS systems have become the benchmark for accurate low-level analysis of trace contaminants across a wide range of high-purity chemicals used in the semiconductor industry. As the first commercial ICP-MS to offer reliable and routine cool plasma operation, the Agilent 4500 Series ICP-MS set the standard for low level analysis of the previously problematic elements Na, K, Ca and Fe. B...
متن کاملPerformance of the Agilent 1100 Series preparative pump at low flow rates Technical Note
The Agilent 1100 Series preparative pump1,2 forms the basis of the Agilent 1100 Series purification system. It is an isocratic high performance pump with dual piston design for a flow rate range of 5–100 ml/min at 400 bar. To form a gradient system two pumps have to be combined. The extremely small delay volume (figure 1) of the mixer and the attached capillaries, about 0.7 ml, allows fast and ...
متن کاملAgilent Techniques and Trends in Signal Monitoring, Frequency Management and Geolocation of Wireless Emitters
Monitoring RF signals in a wireless environment is often required by a variety of wireless equipment operators, facility and test managers and government agencies. Signal monitoring applications can range from compliance of carrier-specific transmissions to the discovery and location of unknown or illegal transmitters. Traditional methods for signal monitoring rely on high performance spectrum ...
متن کاملUnmatched Removal of Spectral Interferences in ICP-MS Using the Agilent Octopole Reaction System with Helium Collision Mode Application
Many routine laboratories have adopted ICP-MS as their primary technique for metals analysis due to its simple operation as a multi-element analyzer. However, despite its higher performance for the targeted removal of specific interferences, collision/reaction cell (CRC) ICP-MS remains relatively understudied in terms of its multielement capability. This work demonstrates that the Agilent 7500c...
متن کاملThe Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS
A new product (Application 460B-00) from Agilent Technologies/WassonECE uses a 5973N GC/MSD (gas chromatograph/mass selective detector) for the determination of trace levels of impurities that are moderate-to-low carbon-content such as oxygenates, mercaptans, sulfides, arsine, and phosphine in ethylene and propylene. This work describes the performance of Application 460B-00 with respect to lin...
متن کامل