Does a front-end nonlinearity confound VEP acuity measures in human infants?

نویسندگان

  • Catherine M Suttle
  • Martin S Banks
  • T.Rowan Candy
چکیده

The visual evoked potential is commonly used to estimate visual acuity in infants. The stimulus used is temporally modulated in order to drive the cortical response. Here it is proposed that distortion products generated by a front-end nonlinearity may contaminate the acuity estimate. Specifically, the nonlinearity might convert temporal modulation of a high spatial frequency grating into apparent whole-field flicker. Thus, the VEP may reflect an artifactual response to a high spatial frequency that is not resolved at the cortical level. If this were the case, one could null or attenuate the flicker response by adding whole-field flicker to the grating stimulus. We looked for such nulling effects in 18 infants aged 6-17 weeks. No consistent evidence was found for the nulling effect, so it was concluded that infant VEP acuity estimates are not significantly contaminated by the hypothesized distortion product.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of pattern VEPs and preferential-looking behavior in 3-month-old infants.

Studies of visual acuity in human infants between 1 and 6 months of age using the visual-evoked potential (VEP) and forced-choice preferential looking (FPL) have shown that acuity is one to two octaves higher by VEP estimates than by FPL estimates. In an attempt to study these differences, the authors obtained both VEP and FPL data from 26 3-month-old infants. VEP data were obtained with gratin...

متن کامل

The effects of luminance on FPL and VEP acuity in human infants.

Grating acuity was measured in 16-week-old human infants. Three measurement techniques were used: forced-choice preferential-looking (FPL), and two visual-evoked-potential (VEP) techniques. The stimuli were counterphase flickering sinewave gratings with a space-average luminance of -1.0 or 2.0 log cd/m2. Slightly different luminance-dependent changes occur between FPL and VEP acuities, suggesti...

متن کامل

Maternal supplementation with docosahexaenoic acid during pregnancy does not affect early visual development in the infant: a randomized controlled trial.

BACKGROUND The docosahexaenoic acid (DHA) intake of pregnant women is lower than estimates of the DHA accretion by the fetus, and recommendations were made to increase the DHA intake of pregnant women. OBJECTIVE The objective of this study was to determine whether the supplementation of pregnant women with DHA improved the visual acuity of infants at 4 mo. DESIGN We conducted a blinded asse...

متن کامل

Infant VEP and preferential looking acuity measured with phase alternating gratings.

Previously, infants' grating acuity was found to be temporally tuned, but adults' grating acuity was not. In infants, acuity was higher for gratings phase alternating at 7.5 and 14 reversals/sec than for stationary gratings and gratings alternating at 2.5 or 23 reversals/sec. Also, when preferential looking (PL) and visually evoked potential (VEP) acuity were estimated with phase alternating gr...

متن کامل

Measurement of position acuity in strabismus and amblyopia: specificity of the vernier VEP paradigm.

PURPOSE An objective measure of positional acuity is desirable in the nonverbal clinical population. This study was conducted to investigate the specificity of the vernier VEP as a measure of positional acuity, evaluating the potential confound of asymmetric motion responses that may be present in some groups of patients. These motion responses could masquerade as position-specific responses, s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Vision Research

دوره 40  شماره 

صفحات  -

تاریخ انتشار 2000