Monitoring Insulin Aggregation via Capillary Electrophoresis
نویسندگان
چکیده
Early stages of insulin aggregation, which involve the transient formation of oligomeric aggregates, are an important aspect in the progression of Type II diabetes and in the quality control of pharmaceutical insulin production. This study is the first to utilize capillary electrophoresis (CE) with ultraviolet (UV) detection to monitor insulin oligomer formation at pH 8.0 and physiological ionic strength. The lag time to formation of the first detected species in the aggregation process was evaluated by UV-CE and thioflavin T (ThT) binding for salt concentrations from 100 mM to 250 mM. UV-CE had a significantly shorter (5-8 h) lag time than ThT binding (15-19 h). In addition, the lag time to detection of the first aggregated species via UV-CE was unaffected by salt concentration, while a trend toward an increased lag time with increased salt concentration was observed with ThT binding. This result indicates that solution ionic strength impacts early stages of aggregation and β-sheet aggregate formation differently. To observe whether CE may be applied for the analysis of biological samples containing low insulin concentrations, the limit of detection using UV and laser induced fluorescence (LIF) detection modes was determined. The limit of detection using LIF-CE, 48.4 pM, was lower than the physiological insulin concentration, verifying the utility of this technique for monitoring biological samples. LIF-CE was subsequently used to analyze the time course for fluorescein isothiocyanate (FITC)-labeled insulin oligomer formation. This study is the first to report that the FITC label prevented incorporation of insulin into oligomers, cautioning against the use of this fluorescent label as a tag for following early stages of insulin aggregation.
منابع مشابه
Imaged Capillary Isoelectric Focusing for Charge-Variant Analysis of Biopharmaceuticals
level: interMediAte Analyzing charge variants of therapeutic proteins is critical for characterizing and monitoring quality attributes of antibodies. Charge variants include deamidation, formation of N-terminal pyroglutamate, aggregation, isomerization, sialylated glycans, antibody fragmentation, and glycation at the lysine residues. In some cases, such changes affect binding, biological activi...
متن کاملTaking Advantage of Electric Field Induced Bacterial Aggregation for the Study of Interactions between Bacteria and Macromolecules by Capillary Electrophoresis.
The quantification of interaction stoichiometry and binding constant between bacteria (or other microorganism) and (macro)molecules remains a challenging issue for which only a few adapted methods are available. In this paper, a new methodology was developed for the determination of the interaction stoichiometry and binding constant between bacteria and (macro)molecules. The originality of this...
متن کاملEffect of Capillary Rinsing Protocol on the Reproducibility of Separation in Capillary Electrophoresis with Indirect UV Detection
Capillary electrophoresis (CE) with indirect UV detection is an interesting analytical method for the analysis of drugs and pharmaceuticals. Good and reproducible capillary quality is needed to develop robust methods and to facilitate method transfer in CE. It is widely accepted that preconditioning procedures are indispensable in capillary electrophoresis in order to achieve reproducibility of...
متن کاملMonitoring surface functionalization of dendrigraft poly-L-lysines via click chemistry by capillary electrophoresis and Taylor dispersion analysis.
Click chemistry by copper-mediated azide/alkyne cycloaddition reaction is known as a very efficient synthetic pathway for chemical coupling and for surface functionalization. The attractiveness of this reaction is due to the selectivity of the reaction of azides and alkynes. Nevertheless, the control of the kinetics of the reaction and the characterization of the reaction products requires the ...
متن کاملThe Diffusion Barrier Technique, practical aspects and data interpretation
Electrophoretic mobility is the rate of movement of a molecule or particle to an electrode in response to an applied electric field. Laser Doppler electrophoresis is commonly used to measure electrophoretic mobility. However, contact of the protein with the electrodes required for the application of the electric field is known to damage proteins and can cause them to denature and aggregate [3]....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 12 شماره
صفحات -
تاریخ انتشار 2011