64-channel array coil for single echo acquisition magnetic resonance imaging.
نویسندگان
چکیده
A 64-channel array coil for magnetic resonance imaging (MRI) has been designed and constructed. The coil was built to enable the testing of a new imaging method, single echo acquisition (SEA) MRI, in which an independent full image is acquired with every echo. This is accomplished by entirely eliminating phase encoding and instead using the spatial information obtained from an array of very narrow, long, parallel coils. The planar pair element design proved to be key in achieving well-localized field sensitivity patterns and isolated elements, the crucial requirements for performing SEA. The matching and tuning of the array elements were accomplished on the coil array printed circuit board using varactor diodes biased over the RF lines. The array was successfully used to obtain SEA images as well as conventional partially parallel images at unprecedented acceleration factors.
منابع مشابه
In order to enable single echo acquisition imaging at a resolution of 64x256, a receiver system and array capable of simultaneous and independent detection of a single echo
1181 Abstract-Parallel imaging methods such as SMASH and SENSE reduce imaging time by using receiver coil sensitivity patterns to reduce requirements for gradient based image localization. This paper describes the first use of a coil array to completely eliminate gradient phase encoding. By using a 64 element planar array and a custom built 64 channel receiver system, 64x256 resolution images w...
متن کاملAccelerated proton echo planar spectroscopic imaging (PEPSI) using GRAPPA with a 32-channel phased-array coil.
Parallel imaging has been demonstrated to reduce the encoding time of MR spectroscopic imaging (MRSI). Here we investigate up to 5-fold acceleration of 2D proton echo planar spectroscopic imaging (PEPSI) at 3T using generalized autocalibrating partial parallel acquisition (GRAPPA) with a 32-channel coil array, 1.5 cm(3) voxel size, TR/TE of 15/2000 ms, and 2.1 Hz spectral resolution. Compared t...
متن کاملPULSAR: A MATLAB Toolbox for Parallel Magnetic Resonance Imaging Using Array Coils and Multiple Channel Receivers
Partial parallel imaging (PPI) techniques using array coils and multichannel receivers have become an effective approach to achieving fast magnetic resonance imaging (MRI). This article presents a Matlab toolbox called PULSAR (Parallel imaging Utilizing Localized Surface-coil Acquisition and Reconstruction) that can simulate the data acquisition and image reconstruction, and analyze performance...
متن کاملScalable multichannel MRI data acquisition system.
A scalable multichannel digital MRI receiver system was designed to achieve high bandwidth echo-planar imaging (EPI) acquisitions for applications such as BOLD-fMRI. The modular system design allows for easy extension to an arbitrary number of channels. A 16-channel receiver was developed and integrated with a General Electric (GE) Signa 3T VH/3 clinical scanner. Receiver performance was evalua...
متن کامل4-channel transceive surface coil array for reduction of EPI-induced artifacts using SENSE and GRAPPA
Introduction In single-shot echo planar imaging (sshEPI) all of the data is acquired following a single RF excitation. Unfortunately, in sshEPI image blurring may occur, due to reduced signal at the edges of k-space; significant geometric distortions can also appear in the final image, because of tissue susceptibility mismatch and off-resonance effects. In functional MRI (fMRI), sshEPI is the p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 54 2 شماره
صفحات -
تاریخ انتشار 2005