Optimal power allocation among multiple heterogeneous servers in a data center

نویسنده

  • Keqin Li
چکیده

In a data center for cloud computing, there are typically multiple heterogeneous servers which provide services in different application domains. For such heterogeneous servers in a data center with different configurations for diversified applications and certain available power, there is a problem of allocating the power to the servers, such that the overall quality of service of the servers in the data center is optimized. We address power constrained performance optimization in a data center with multiple heterogeneous servers. We consider the problem of optimal power allocation among multiple heterogeneous servers, i.e., minimizing the average task response time of multiple heterogeneous computer systems with energy constraint. Each server is treated as a queueing system and the average task response time in a data center with multiple servers is formulated as a function of power allocations to the servers. The average task response time is minimized subjected to the constraint that the total effective power consumption of all the servers does not exceed a given power limit. We develop an algorithm to find the optimal solution and demonstrate numerical data. We also develop several closed-form heuristic solutions and show that they are very close to the optimal solution. Our approach provides an analytical way of studying the power-performance tradeoff at the data center level. © 2011 Elsevier Inc. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Jointly power and bandwidth allocation for a heterogeneous satellite network

Due to lack of resources such as transmission power and bandwidth in satellite systems, resource allocation problem is a very important challenge. Nowadays, new heterogeneous network includes one or more satellites besides terrestrial infrastructure, so that it is considered that each satellite has multi-beam to increase capacity. This type of structure is suitable for a new generation of commu...

متن کامل

MultiAmdahl: Optimal Resource Allocation in Heterogeneous Architectures

Future multiprocessor chips will integrate many different units, each tailored to a specific computation. When designing such a system, the chip architect must decide how to distribute limited system resources such as area, power, and energy among the computational units. We extend MultiAmdahl, an analytical optimization technique for resource allocation in heterogeneous architectures, for ener...

متن کامل

Reducing Power Consumption in Data Centers by Jointly Considering VM Placement and Flow Scheduling

Two important components that consume the majority of IT power in data centers are the servers and the Data Center Network (DCN). Existing works fail to fully utilize power management techniques on the servers and in the DCN at the same time. In this paper, we jointly consider VM placement on servers with scalable frequencies and flow scheduling in the DCN, to minimize the overall system’s powe...

متن کامل

Maximal covering location-allocation problem with M/M/k queuing system and side constraints

  We consider the maximal covering location-allocation problem with multiple servers. The objective is to maximize the population covered, subject to constraints on the number of service centers, total number of servers in all centers, and the average waiting time at each center. Each center operates as an M/M/k queuing system with variable number of servers. The total costs of establishing cen...

متن کامل

Chip Temperature-Based Workload Allocation for Holistic Power Minimization in Air-Cooled Data Center

Minimizing the energy consumption is a dominant problem in data center design and operation. To cope with this issue, the common approach is to optimize the data center layout and the workload distribution among servers. Previous works have mainly adopted the temperature at the server inlet as the optimization constraint. However, the inlet temperature does not properly characterize the server’...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012