Why Charcoal Devices Must Be Analyzed Soon after Measurement: Uncertainty and Minimum Detectable
نویسنده
چکیده
The value of a radon measurement is meaningless unless one knows two additional pieces of information about the measurement; the total uncertainty and the Minimum Detectable Concentration (MDC). These statistics are particularly important when making measurements with devices that capture radon and then are analyzed later; such as grab scintillation cells and charcoal devices. During the delay between sampling and analysis, the quantity of radon in the device constantly decreases due to its decay with a half-life of about 3.8 days. Using 4-inch charcoal canisters as an example, and using typical values of analysis parameters, it is shown that the total uncertainty and the MDC for the measurement both increase with time after the sampling period and can become unacceptable, thus rendering the measurement useless. This illustrates the importance of analyzing these devices as quickly as possible after sampling.
منابع مشابه
The evaluation of minimum detectable phantom thickness change using a scanning liquid filled ion chamber EPID dose response
ABSTRACTBackground: Although Electronic Portal imaging Devices (EPIDs) have originally developed for positioning verification, they can also be used for dosimetric purposes. In the current work, the dose response of minimum detectable thickness of a Scanning Liquid filled Ion Chamber EPID, SLIC-EPID, and the variation of transmitted dose with the shift of inhomogeneity inside of phantom was al...
متن کاملOptimization of measurement counting time in Gamma-ray spectrometry of soil samples
The method of optimal measurement counting time in Gamma spectrometry for soil samples was studied. Gamma spectrometry was done based on minimum detectable activity using the HPGe- p type with efficiency of 30% and FWHM 1.7keV (for 1.33 MeV 60Co). The samples were IAEA-RG Th-1, IAEA-RGU-1 and IAEA-RGK-1 prepared in bottles. The measurements were done for 12 different counting times from 5 min t...
متن کاملThe Relationship among Glycemic, Small Intestinal Transit and Insulinemic States in Normal Mice
Gastrointestinal (GI) complications during diabetes mellitus (DM) are common. Attempts to ascribe changes in the glycemic state to the altered GI (gastrointestinal) motility in experimental models yielded varied results. In the present study the possible cause-effect relationship between the changes in the glycemic, insulinemic states and small intestinal transit (SIT) in normal mice was examin...
متن کاملRADON MEASUREMENT OA - PRACTICE vs PROTOCOLS
The EPA radon measurement device protocols of July 1992 specify several recommendations for quality assurance, which are now mandated as requirements by several states. These QA requirements include 1) annual calibration of measurement systems, 2) known spike measurements at a rate of 3 per 100 (minimum of 3 per year or a maximum of 6 per mo~th), 3) duplicates at a rate of 10 percent of devices...
متن کاملمحاسبه فاصله عدم قطعیت بر پایه آنتروپی شانون و تئوری دمپستر-شافر از شواهد
Abstract Dempster Shafer theory is the most important method of reviewing uncertainty for information system. This theory as introduced by Dempster using the concept of upper and lower probabilities extended later by Shafer. Another important application of entropy as a basic concept in the information theory can be used as a uncertainty measurement of the system in specific situation In th...
متن کامل