Postprocedural radial artery occlusion rate using a sheathless guiding catheter for left ventricular endomyocardial biopsy performed by transradial approach

نویسندگان

  • Behrouz Kherad
  • Clemens Köhncke
  • Frank Spillmann
  • Heiner Post
  • Michel Noutsias
  • Burkert Pieske
  • Florian Krackhardt
  • Carsten Tschöpe
چکیده

BACKGROUND For coronary interventions the arterial access via the radial artery is associated with fewer vascular access site complications, and has been shown to reduce major bleeding when compared to the femoral approach. But the endomyocardial biopsy (EMB) approach is usually done by a transfemoral or cervical access known to be associated with an increased risk of artery puncture and its potential complications (i.e., false aneurysm, artery-venous fistula) and needs post-procedural immobilization. A transradial approach for EMBs is not standardized. The aim of our study is to validate safety and efficacy of the transradial access approach for left ventricular EMB, and to define patients eligible for a safe and successful procedure. METHODS AND RESULTS We evaluated the transradial access using a 7.5 F sheathless multipurpose guiding catheter to obtain EMBs from the left ventricle (LV). 18 patients were included. The transradial success rate was 100% (18/18). There were no periprocedural cardiac complications. Immediate post-procedural ambulation could be achieved in all patients. Although radial artery pulse was confirmed by ultrasonic vascular Doppler after removal of the guide in 100% (18/18) of the patients, 50% (9/18) of the patients showed occlusion of the radial artery RAO) by duplex sonography proximal to the access site. 33% (3/9) of the patients in the RAO group and 11,1% (1/9) of the patients in the patent radial artery (RAP) group, respectively, experienced mild pain after the procedure in the right lower arm. Colour Doppler ultrasonography of the right radial artery performed 24 h after the procedure revealed radial occlusion in 50% (9/18) of the patients. The diameter of the radial artery was significantly smaller in the RAO group (p = 0,034), peak systolic velocity (PSV) of the right ulnar artery was significantly higher in the RAO group (p = 0.012). Peak systolic velocity of the opposite radial artery was significantly lower in the RAO group (p = 0,045). Gender, sex, diabetes, radial artery inner diameter ≤2.5 mm and lower peak systolic velocity of < 50 cm/s are predictors of RAO. CONCLUSION The present study demonstrates the safety and efficacy of a transradial access for EMB using a highly hydrophilic sheathless guiding catheter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transradial percutaneous coronary intervention for chronic total occlusion of coronary artery disease using sheathless standard guiding catheters

OBJECTIVES Our aim was to evaluate the feasibility and safety of routine transradial approach (TRA) percutaneous coronary intervention (PCI) for chronic total occlusion (CTO) lesions using the sheathless technique with standard guiding catheters. BACKGROUND Transradial approach PCI was applied for CTO lesions. A major limitation of TRA CTO PCI is the inability to use large guiding catheters b...

متن کامل

Feasibility of Transradial Coronary Intervention Using a Sheathless Guiding Catheter in Patients With Small Radial Artery

BACKGROUND AND OBJECTIVES Transradial coronary angiography and intervention are increasing in frequency due to lower major vascular access site complications and the potential for early mobilization. However, the small size of the radial artery (RA) is a major limitation of this technique. A sheathless guiding catheter (GC) has recently been introduced that has a 1-2 French smaller diameter com...

متن کامل

Transradial retrograde recanalization of totally occluded left anterior descending artery using a single 7 fr guiding catheter.

The retrograde approach for percutaneous coronary intervention (PCI) of chronic total occlusion (CTO) has helped to improve the success rate. It is usually performed through collateral connections that originate from the contralateral coronary artery to the occluded one and by using two arterial accesses and two guiding catheters, most commonly from the femoral approach. A first reported case o...

متن کامل

Transradial and transulnar access for iliac artery interventions using sheathless guiding systems: A feasibility study

PURPOSE Our aim was to evaluate the acute success and complication rates of the transradial and transulnar access for iliac artery stenting using sheathless guiding systems. METHODS Clinical and angiographic data from 156 consecutive patients with symptomatic iliac artery stenosis who were treated with transradial or transulnar access were evaluated. All patients underwent Duplex ultrasound b...

متن کامل

Safety and feasibility of the new 5 Fr Glidesheath Slender.

The aim of this study was to evaluate the safety and feasibility of the new 5 Fr Glidesheath Slender (GSS). The transradial (TR) approach has become popular because of several advantages, such as a reduced rate of vascular access site complications. However, because the radial artery is narrow, a limitation of TR access is the potential for artery spasm or occlusion. Studies of radial artery si...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2016