The response of the femur to trauma, a foreign body, and a direct electrical current in mice.
نویسندگان
چکیده
The idea that electricity may be used by orthopedists to repair injured and diseased bone and by orthodontists to help straighten crooked teeth is being popularized."' It started when investigators found that piezoelectrical-type potentials are generated in stressed bone."' Areas of bone under compression develop negative potentials, whereas areas under tension develop positive potentials. It has long been known that when a living bone is forcibly bent it will become thicker on the compressed concave side and thinner on the tensed convex side.' Negative potentials that occur where the bone becomes thicker and positive potentials that occur where the bone becomes thinner may or may not be causative factors in the remodeling of the bone. Although the generation of piezoelectrical potentials in stressed bone is not the same as the passage of an exogeneous direct current through unstressed bone, Lavine, et al.' reported significantly more new bone formation in drilled rabbit femurs receiving a direct current than in non-electrically treated drilled femurs. Bassett, et al.7 reported massive production of endosteal bone around every cathode of insulated battery implants in one femur each of 12 dogs. The electrodes projected into the medullary cavity of the femur and a direct current of 10 ,uA or 100 pA was maintained for 14-21 days. They noted an increased cellularity at the cathode during bone formation and felt it was the result of mitoses. Other investigators performed similar experiments using the femur in rabbits and obtained equivocal or negative results." O'Connor, et al.' used detailed directions supplied by Bassett to duplicate his experimente on the dog femur. They found that the cathode did not always have the most bone formation around it. In two dogs it had the least. We performed an experiment on mice that was similar to those above; however, some modifications were made that we felt were improvements in experimental design.
منابع مشابه
An investigation of the effects of osteoporosis, impact intensity and orientation on human femur injuries: a parametric finite element study
Objective: Femur is the strongest, longest and heaviest bone in the human body. Due to the great importance of femur in human body, its injury may cause large numbers of disabilities and mortality. Considering various effective parameters such as mechanical properties, geometry, loading configuration, etc. can propel the study to the trustable results.. Methods: A 3D finite element model of the...
متن کاملUnusual Presentation of Metallic Foreign Body Aspiration after Penetrating Neck Trauma
A 25 year-old Construction worker underwent neck laceration following penetrating neck trauma in a falling incident. The 3rd tracheal ring was injured which was initially repaired and the patient was discharged in good general condition. (Figure 1 shows the patient’s neck view after discharge from hospital).Two months later the patient was again admitted due to provocative coughing and a metal ...
متن کاملEvaluating Anthropometric Dimensions of the Femur Using Direct and Indirect Methods
Introduction: The human anthropometric characteristics are surveyed in anthropology. Anthropology is used in archeology, rehabilitation and legal medicine. The purpose of this study was to determine femur which has a special place in the science of anthropometry. Methods: To measure the femur, both direct and indirect methods was used. The direct method of measuring the 113 femur in dissection...
متن کاملTreatment of Colon Carcinoma Tumors by Electrolysis: Effect of Electrical Dose and Polarity
Introduction: As a physical treatment, electrochemical therapy (ECHT) has provided an effective and useful approach for treating localized tumors. The chemical changes due to a direct electric current destroy the tumor. This study evaluates the effect of electrical dose and polarity on the efficacy of the treatment of a colon tumor model. Materials and Methods: In order to in...
متن کاملAppendicitis Caused by Metallic Foreign Body in the Appendix
Although uncommon, different kinds of foreign bodies, most of which metallic, have been reported to enter the appendix. The present report describes a case with a metallic foreign body-induced appendicitis, and makes suggestion in regards to the diagnosis and management of the problem. A metallic foreign body was accidentally observed in the right lower quadrant region in an abdominal X-ray tak...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Yale Journal of Biology and Medicine
دوره 43 شماره
صفحات -
تاریخ انتشار 1970