Influence of balloon pressure inflation in patients undergoing primary coronary stent implantation during acute myocardial infarction. A quantitative coronary angiography analysis.

نویسندگان

  • Luiz Alberto Mattos
  • Amanda G Sousa
  • Aurea Chaves
  • Fausto Feres
  • Ibraim Pinto
  • Luiz Tanajura
  • Marinella Centemero
  • Alexandre Abizaid
  • Ana C Seixas
  • Andréa Abizaid
  • Galo Maldonado
  • Rodolfo Staico
  • J Eduardo M Sousa
چکیده

OBJECTIVE To verify the influence of moderate- or high-pressure balloon inflation during primary coronary stent implantation for acute myocardial infarction. METHODS After successful coronary stent implantation, 82 patients were divided into 2 groups according to the last balloon inflation pressure: group 1 (> or = 12 to < 16 atm) and group 2 (> or = 16 to 20 atm), each with 41 cases. All patients underwent late coronary angiography. RESULTS In group 1, the mean stent deployment pressure was 13.58 +/- 0.92 atm, and in the group 2 it was 18.15 +/- 1.66 atm. Stents implanted with moderate pressures (> or = 12 to < 16 atm) had a significantly smaller post-procedural minimal lumen diameter, compared to with those with higher pressure, with lesser acute gain (2.7 +/- 0.4 mm vs 2.9 +/- 0.4 mm; p = 0.004), but the late lumen loss (0.9 +/- 0.8 mm vs 0.9 +/- 0.6 mm) and the restenosis (22% vs. 17.1%) and target-vessel revascularization rates (9.8% vs 7.3%) were similar between the groups. CONCLUSION During AMI stenting, the use of high pressures (> or = 16 atm) did not cause a measurable improvement in late outcome, either in the late loss, its index, and the net gain, or in clinical and angiographic restenosis rates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Management of a large coronary artery aneurysm with graft-coated stent during the acute phase of myocardial infarction

Coronary aneurysms in adults are rare clinical entities. Herein, we presented a 54-year-old man who was admitted with an acute extensive anterior myocardial infarction. The emergency coronary angiography revealed an isolated large aneurysm at the proximal segment of the left anterior descending coronary artery. The patient was successfully treated with a graft-coated stent

متن کامل

Acute clinical and angiographic results with the new AVE Micro coronary stent in bailout management.

To determine the feasibility and safety of development of this new stent, we deployed 28 AVE Micro stents in 23 native coronary artery lesions in 20 patients who developed acute or threatened closure after balloon angioplasty (BA). Ten stents were deployed in the left anterior descending artery, 10 in the circumflex, and 8 in the right coronary artery. Luminal dimensions were measured using a c...

متن کامل

Acute Thrombotic Occlusion of Right Coronary and Left Circumflex Coronary Arteries in a Patient with Antiphospholipid Syndrome: Successful Stent Implantation

Antiphospholipid syndrome is a rare disorder. Acute myocardial infarction is uncommon among these patients. Here we report a case of a 44-year-old man with antiphospholipid syndrome admitted for acute inferior myocardial infarction. Performed coronary angiography revealed that both the right coronary and the left circumflex coronary arteries were occluded by thrombi. We successfully performed p...

متن کامل

Influence of balloon pressure during stent placement in native coronary arteries on early and late angiographic and clinical outcome: A randomized evaluation of high-pressure inflation.

BACKGROUND High-pressure dilatation is considered a better stent placement strategy, but this has not yet been proved by appropriately designed studies. The objective of this randomized trial was to assess the role of high-pressure dilatation in the early and late outcome of patients undergoing coronary stent placement. METHODS AND RESULTS Consecutive patients with coronary stent placement we...

متن کامل

Clinical experience with the Wiktor stent in native coronary arteries and coronary bypass grafts.

OBJECTIVES To evaluate the results of implantation of Wiktor tantalum wire coronary stents in stenosed or occluded coronary vessels or in saphenous vein bypass grafts. DESIGN A retrospective analysis of clinical and angiographic data from patients treated with tantalum wire stents implanted by one operator at two centres. PATIENTS 52 patients undergoing conventional balloon angioplasty had ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arquivos brasileiros de cardiologia

دوره 80 3  شماره 

صفحات  -

تاریخ انتشار 2003