Enclosed Electronic System for Force Measurements in Knee Implants

نویسندگان

  • David Forchelet
  • Matteo Simoncini
  • Arash Arami
  • Arnaud Bertsch
  • Eric Meurville
  • Kamiar Aminian
  • Peter Ryser
  • Philippe Renaud
چکیده

Total knee arthroplasty is a widely performed surgical technique. Soft tissue force balancing during the operation relies strongly on the experience of the surgeon in equilibrating tension in the collateral ligaments. Little information on the forces in the implanted prosthesis is available during surgery and post-operative treatment. This paper presents the design, fabrication and testing of an instrumented insert performing force measurements in a knee prosthesis. The insert contains a closed structure composed of printed circuit boards and incorporates a microfabricated polyimide thin-film piezoresistive strain sensor for each condylar compartment. The sensor is tested in a mechanical knee simulator that mimics in-vivo conditions. For characterization purposes, static and dynamic load patterns are applied to the instrumented insert. Results show that the sensors are able to measure forces up to 1.5 times body weight with a sensitivity fitting the requirements for the proposed use. Dynamic testing of the insert shows a good tracking of slow and fast changing forces in the knee prosthesis by the sensors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation of Anthropometric Measurements of Proximal Tibia in Iranian Knees with Size of Current Tibial Implants

of the Caucasian population. The purpose of this study was to investigate the morphometry of the proximal tibia in thestandard resected surface of total knee arthroplasty (TKA).Methods: In this descriptive study, the anthropometric data of the proximal tibia were measured in 132 knees (80 malesand 52 females) using magnetic resonance imaging in 2015. The collected data include...

متن کامل

Anthropometric Measurements of Distal Femur to Design the Femoral Component of Total Knee Arthroplasty for the Iranian Population

Background: Acquiring knowledge about anatomic and geometric quantities of bones is among the most vitalparameters in orthopedic surgery that has a significant effect on the treatment of various disorders and subsequentoutcomes. The aim of this study was to obtain anthropometric information for distal femur in order to compare withsimilar dimensions of prosthesis used in total...

متن کامل

بررسی تکرارپذیری نیروی عکس العمل زمین حین استفاده از ابزار اعمال اغتشاش اندام تحتانی در حرکت ایستادن روی یک پا

Introduction: The aim of the current study was to measure ground reaction force and center of pressure (COP) during lower extremity perturbation in single leg standing whit knee flexion and extension in healthy subjects, in addition to revealing reliability of the device used for the related perturbation for using another studies, reliability is one of the characteristic of measuring instrumen...

متن کامل

Human Knee Prosthesis Equipped with Force Sensors

In-vivo monitoring of human knee implants after total arthroplasty increases the knowledge about articular motion and loading conditions. The proposed knee prosthesis equipped with force sensors executes force measurements in polyethylene human knee prosthesis by two sensorized metal bars positioned under the femoral condyles and fully contained in the polyethylene insert. In this paper, a new ...

متن کامل

A new tibial coordinate system improves the precision of anterior-posterior knee laxity measurements: A cadaveric study using Roentgen stereophotogrammetric analysis

Roentgen stereophotogrammetric analysis (RSA) can be used to measure changes in anterior-posterior (A-P) knee laxity after anterior cruciate ligament (ACL) reconstruction. Previous measurements of A-P knee laxity using RSA have employed a tibial coordinate system with the origin placed midway between the tips of the tibial-eminences. However, the precision in measuring A-P knee laxity might be ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2014