Effect of Different Disinfection Protocols on Microbial and Biofilm Contamination of Dental Unit Waterlines in Community Dental Practices

نویسندگان

  • Laura Dallolio
  • Amalia Scuderi
  • Maria S. Rini
  • Sabrina Valente
  • Patrizia Farruggia
  • Maria A. Bucci Sabattini
  • Gianandrea Pasquinelli
  • Anna Acacci
  • Greta Roncarati
  • Erica Leoni
چکیده

Output water from dental unit waterlines (DUWLs) may be a potential source of infection for both dental healthcare staff and patients. This study compared the efficacy of different disinfection methods with regard to the water quality and the presence of biofilm in DUWLs. Five dental units operating in a public dental health care setting were selected. The control dental unit had no disinfection system; two were disinfected intermittently with peracetic acid/hydrogen peroxide 0.26% and two underwent continuous disinfection with hydrogen peroxide/silver ions (0.02%) and stabilized chlorine dioxide (0.22%), respectively. After three months of applying the disinfection protocols, continuous disinfection systems were more effective than intermittent systems in reducing the microbial contamination of the water, allowing compliance with the CDC guidelines and the European Council regulatory thresholds for drinking water. P. aeruginosa, Legionella spp, sulphite-reducing Clostridium spores, S. aureus and β-haemolytic streptococci were also absent from units treated with continuous disinfection. The biofilm covering the DUWLs was more extensive, thicker and more friable in the intermittent disinfection dental units than in those with continuous disinfection. Overall, the findings showed that the products used for continuous disinfection of dental unit waterlines showed statistically better results than the intermittent treatment products under the study conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Bilpron on the reduction of colony counts of some bacteria existing in dental unit waterlines

Effects of Bilpron on the reduction of colony counts of some bacteria existing in dental unit waterlines Dr. SM. Safavi* - Dr. SA. Ghaemmaghami** - Dr. M. Aminzadeh*** - Dr. K. Alavi****- S. Taheri***** *- Assistant Professor of Orthodontics Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. **- Professor and Chief of Diagnosis and Oral Diseases – Faculty of Dentist...

متن کامل

Impact of a Risk Management Plan on Legionella Contamination of Dental Unit Water

The study aimed to assess the prevalence of Legionella spp. in dental unit waterlines of a dental clinic and to verify whether the microbiological parameters used as indicators of water quality were correlated with Legionella contamination. A risk management plan was subsequently implemented in the dental health care setting, in order to verify whether the adopted disinfection protocols were ef...

متن کامل

Evaluation of Bacterial Contamination Level of Waterlines in Dental Units in Dentistry School of Qom University of Medical Sciences in 2018

Background and Objectives: According to hazardous infection possibility in patients with a weakened immune system, old adults, and children, microbial contamination in the waterlines of dental units has become a recent concern. The aim of the present study was to evaluate the microbial contamination in dental unit waterlines in the School of Dentistry, Qom University of Medical Sciences, Qom, I...

متن کامل

Microbial contamination of dental unit waterlines.

The specific structure of dental units favours the presence of biofilm and microbial contamination of the dental unit waterlines (DUWL) water. The ability of bacteria to colonize surfaces and to form biofilm in water supply tubes, including DUWL, is a common phenomenon, which has been well documented, just as with difficulties in biofilm removal and prevention of its regrowth. Microorganisms fr...

متن کامل

Substantivity of hypochlorous acid-based disinfectant against biofilm formation in the dental unit waterlines

OBJECTIVE The purpose of the study was to examine the substantivity of a new disinfectant against biofilm formation in the dental unit waterlines. MATERIALS AND METHODS Twenty dental units were selected for the study and divided into two groups: Group A (dental unit waterlines treated with the disinfectant) and Group B (untreated dental unit waterlines). Biofilm formation was monitored in bot...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2014