Differences in the mechanical properties of calcaneal artificial specimens, fresh frozen specimens, and embalmed specimens in experimental testing.
نویسندگان
چکیده
BACKGROUND Artificial calcanei, fresh-frozen cadaver specimens, and embalmed cadaver specimens were compared in experimental testing under biocompatible loading to clarify the biocompatibility of artificial calcaneal specimens for implant testing. METHODS Two different artificial calcaneal bone models (Sawbone, Pacific Research Laboratories, Vashon, WA, and Synbone, Synbone Inc., Davos, Switzerland), embalmed cadaver calcaneal specimens (bone density, 313.1 +/- 40.9 g/cm2; age, 43.8 +/- 7.9 years), and fresh-frozen cadaver calcanei (bone density, 238.5 +/- 30.0 g/cm2; age, 44.4 +/- 8.2 years) were used for testing. Seven specimens of each model or cadaver type were tested. A mechanical testing machine (Zwick Inc., Ulm, Germany) was used for loading and measurements. Cyclic loading (preload 20 N, load was increased every 100 cycles by 100 N from 1,000 to 2,500 N, 0.5 mm/s) and load to failure (0.5 mm/s) were performed. The loads were applied through an artificial talus in a physiological loading direction. The displacement of the posterior facet in the primary loading direction was measured. RESULTS The four different specimen groups showed different stability and different displacement in the primary loading direction during cyclic loading. The variation of the maximal displacement in the primary loading direction for the entire cyclic loading was higher in artificial specimens than in the cadaver specimens. CONCLUSIONS Artificial calcanei (Sawbone, Synbone) showed different biomechanical characteristics than cadaver bones (embalmed and fresh-frozen) in this experimental setup with biocompatible cyclic loading. These results do not support the use of artificial calcanei for biomechanical implant testing. Fresh-frozen and embalmed specimens seem to be equally adequate for mechanical testing. The low variation of mechanical strength in the unpaired cadaver specimens suggests that the use of PAIRED specimens is not necessary.
منابع مشابه
Embalmed and fresh frozen human bones in orthopedic cadaveric studies: which bone is authentic and feasible?
BACKGROUND AND PURPOSE The most frequently used bones for mechanical testing of orthopedic and trauma devices are fresh frozen cadaveric bones, embalmed cadaveric bones, and artificial composite bones. Even today, the comparability of these different bone types has not been established. METHODS We tested fresh frozen and embalmed cadaveric femora that were similar concerning age, sex, bone mi...
متن کاملEnvironmental Effects on Mechanical Properties of Glass/Epoxy and Fiber Metal Laminates, Part I: Hygrothermal Aging
In this article, the effect of hygrothermal aging on mechanical properties of fiber metal laminates (FMLs) and E-glass/epoxy (GE) composites is investigated. First, FML and GE specimens were built using wet lay-up technique under vacuum pressure. Hygrothermal aging simulation was then carried out on both specimen types in distilled water at a constant temperature of 90 °C for 5 weeks. The resul...
متن کاملMechanical strength of cortical allografts with gamma radiation, in Acta Orthop Belg
versus ethylene oxide (ETO) sterilization on the mechanical strength of cortical bone grafts. Tibias were collected from cadavers of mature goats. Sixty test specimens were randomized into four groups : fresh (no processing), frozen (freezing at –70°C), gamma-irradiated, and ETO-sterilized specimens. Torsion, three-point bending, and compression testing were separately performed with a material...
متن کاملZinc Chloride, A New Material for Embalming and Preservation of the Anatomical Specimens
Introduction: Formaldehyde is one of the most common chemicals used for embalming and as a result teaching anatomy. Because of the adverse effects of formaldehyde on human health and also its environmental complications, this study was conducted to investigate a new solution containing zinc chloride for fixation and preservation of anatomical specimens. Methods: In this study, we used 40...
متن کاملExperimental Investigation of Behavior of Glass Fiber Reinforced Concrete (GFRC)
The paper presents the results of casting and testing of 264 GFRC specimens. The glass fibers were 25 mm long, with the aspect ratio (L/D) ranging between 1250 and 3570. The parameters studied were the ratio (by weight) of fibers to cement, i.e. F/C=0%, 1.5%, 3%, and 4.5%, and the ratio of coarse to fine aggregates (gravel to sand), i.e. G/S=1.1, 0.7 and 0.2. In total, 12 mix designs were selec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Foot & ankle international
دوره 27 12 شماره
صفحات -
تاریخ انتشار 2006