Coping with Off-Resonance Effects and Gradient Imperfections in Parallel Transmission Experiments

نویسندگان

  • J. T. Schneider
  • M. Haas
  • J. Hennig
  • S. Junge
  • W. Ruhm
  • P. Ullmann
چکیده

Introduction: Parallel transmission has proven to provide good results for spatially selective excitation with reasonable RF-pulse durations [1]. For best spatial definition, exact matching of RF-pulses with a simultaneously played out gradient waveform, which defines a k-space position for every point in time, is crucial. However off-resonance effects and gradient imperfections may lead to distortions in the excited pattern. In this study several approaches are presented and compared which allow the mitigation of the impact of such inaccuracies by measuring and pre-calibrating the k-space trajectory and by basing the RF pulse calculation on such measured data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

VERSE‐guided parallel RF excitations using dynamic field correction

In parallel RF pulse design, peak RF magnitudes and specific absorption rate levels are critical concerns in the hardware and safety limits. The variable rate selective excitation (VERSE) method is an efficient technique to limit the peak RF power by applying a local-only RF and gradient waveform reshaping while retaining the on-resonance profile. The accuracy of the excitation performed by the...

متن کامل

Optimized distortion correction technique for echo planar imaging.

A new phase-shifted EPI pulse sequence is described that encodes EPI phase errors due to all off-resonance factors, including B(o) field inhomogeneity, eddy current effects, and gradient waveform imperfections. Combined with the previously proposed multichannel modulation postprocessing algorithm (Chen and Wyrwicz, MRM 1999;41:1206-1213), the encoded phase error information can be used to effec...

متن کامل

Reducing gradient imperfections for spiral magnetic resonance spectroscopic imaging.

Spiral k-space magnetic resonance spectroscopic imaging (MRSI) requires high performance from gradient hardware systems. During the readout phase, oscillating gradients are continuously played out, which can cause undesired effects. These effects on the quality of SI data are non-intuitive because of their time-varying nature. In this work we describe the effects of undesirable gradient perform...

متن کامل

Primary resonance of an Euler-Bernoulli nano-beam modelled with second strain gradient

In the present manuscript, the second strain gradient (SSG) is utilized to investigate the primary resonance of a nonlinear Euler-Bernoulli nanobeam is analyzed in this paper...

متن کامل

T2*-compensated Transmit SENSE RF pulses

Introduction Selective excitation in more than one dimension is plagued by effects that are due to the long duration of the RF pulses and gradient trajectories needed. B0 off-resonances, for example, dephase magnetization contributions created at different points in time during the excitation process. As a consequence, these contributions do not add up consistently which causes artifacts in the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008