Use of time interval histographic output from echo-Doppler to detect left-to-right atrial shunts.

نویسندگان

  • S J Goldberg
  • J C Areias
  • S E Spitaels
  • V H de Villeneuve
چکیده

The primary purpose of this study was to attempt to select, by examination of the time interval histogram (TIH) output of a range gated pulsed Doppler (RGPD), all children with left-to-right shunt at the atrial level from a pool of 57 children. Fifty-four of the children had various forms of acyanostic cardiac disease. A secondary purpose was to identify any associated lesions in those children with atrial defects. Examiners were unfamiliar with the children and their diagnoses. Results were interpreted independently by two examiners. Detection of diastolic TIH dispersion was used when studying the right atrial outflow tract to separate children with atrial left-to-right shunts from control children. All controls were judged negative by this technique, and 13 of 14 children with atrial shunts were detected by both examiners; the 14th was detected by one examiner. Of a total of 308 TIH decisions on the atrial shunt group, 298 were made identically by both examiners for a 97.7% agreement, demonstrating the objectivity of the method. This study demonstrated the usefulness of the TIH evaluation, indicating that continued investigation and equipment improvements are warranted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cor Triatriatum Sinistrum Presenting as Cyanotic Congenital Heart Disease A Rare Case Report

  Cor triatriatum is an acyanotic congenital heart disease. We present a rare case of cor triatriatum sinistrum in a 6-month-old female infant who was presented with cyanosis and failure to thrive. The 2D transthoracic echocardiography and the Doppler color flow imaging showed a proximal venous chamber communicating to the distal left atrium  through restrictive opening to the low-pressure, dis...

متن کامل

Detection and exclusion of interatrial shunts by two-dimensional echocardiography and peripheral venous injection.

Two-dimensional echocardiography (2-D echo) was used with peripherally injected contrast material to detect interatrial shunts in 33 patients. Group 1 consisted of 11 patients having classic clinical findings of atrial septal defect. Group 2 consisted of 12 patients with problems requiring that atrial shunting be excluded. Group 3 (control group) consisted of 10 patients undergoing cardiac cath...

متن کامل

The Effect of Bronchial Asthma on Interatrial Electromechanical Delay Coupling Obtained Using Tissue Doppler Imaging

Background: Asthma is a predisposing factor for the development of atrial fibrillation. Asthma disturbs the electrophysiology in the right and left atrium. The aim of this study was to evaluate atrial electromechanical delay by coupling obtained from tissue Doppler imaging (TDI) in children. Methods: A cross-sectional study was conducted on 50 patients with Bronchial Asthma, compared with 50 hea...

متن کامل

Contrast Enhanced Echocardiography for Detection of Intrapulmonary Shunts in Liver Transplant Candidates

Background: Intrapulmonary vascular abnormalities associated with liver cirrhosis may result in intrapulmonary right-to-left shunt and hypoxemia. The aim of this study was to use contrast enhanced echocardiography to detect intrapulmonary vascular abnormalities in patients with liver cirrhosis candidates for liver transplantation. Methods: One hundred and two adult patients underwent contrast e...

متن کامل

Doppler-Derived Myocardial Performance Index in Healthy Children in Shiraz

Background: Assessment of myocardial function is essential in heart disease, but in regard to systolic and diastolic functions such evaluation has limitation. Ejection fraction is difficult to assess in abnormally-shaped ventricles, and diastolic inflow velocity pattern may be fused because of tachycardia. Objective: A myocardial performance index (MPI) or Tei index has been developed for adult...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 58 1  شماره 

صفحات  -

تاریخ انتشار 1978