Ultimate and practical limits of fluid-based mass detection with suspended microchannel resonators
نویسندگان
چکیده
Suspended microchannel resonators SMRs are an innovative approach to fluid-based microelectromechanical mass sensing that circumvents complete immersion of the sensor. By embedding the fluidics within the device itself, vacuum-based operation of the resonator becomes possible. This enables frequency shift-based mass detection with high quality factors, and hence sensitivity comparable to vacuum-based micromechanical resonators. Here we present a detailed analysis of the sensitivity of these devices, including consideration of fundamental and practical noise limits, and the important role of binding kinetics in sensing. We demonstrate that these devices show significant promise for protein detection. For larger, biologically-important targets such as rare whole virions, the required analysis time to flow sufficient sample through the sensor can become prohibitively long unless large parallel arrays of sensors or preconcentrators are employed. © 2010 American Institute of Physics. doi:10.1063/1.3475151
منابع مشابه
Suspended microchannel resonators for biomolecular detection
We have demonstrated a new approach for detecting biomolecular mass in the aqueous environment. Known as the suspended microchannel resonator (SMR), target molecules flow through a suspended microchannel and are captured by receptor molecules attached to the interior channel walls [1]. As with other resonant mass sensors, the SMR detects the amount of captured target molecules via the change in...
متن کاملSuspended microchannel resonators with piezoresistive sensors.
Precision frequency detection has enabled the suspended microchannel resonator (SMR) to weigh single living cells, single nanoparticles, and adsorbed protein layers in fluid. To date, the SMR resonance frequency has been determined optically, which requires the use of an external laser and photodiode and cannot be easily arrayed for multiplexed measurements. Here we demonstrate the first electr...
متن کاملHighly Sensitive Measurement of Liquid Density in Air Using Suspended Microcapillary Resonators
We report the use of commercially available glass microcapillaries as micromechanical resonators for real-time monitoring of the mass density of a liquid that flows through the capillary. The vibration of a suspended region of the microcapillary is optically detected by measuring the forward scattering of a laser beam. The resonance frequency of the liquid filled microcapillary is measured for ...
متن کاملElectronic Readout of Microchannel Resonators for Precision Mass Sensing in Solution
Microfabricated transducers have enabled new approaches for detection of biomolecules and cells. Integration of electronics with these tools simplify systems and provide platforms for robust use outside of the laboratory setting. Suspended microchannel resonators (SMRs) are sensitive microfluidic platforms used to precisely measure the buoyant mass of single cells and monolayers of protein in f...
متن کاملLabel-free biomarker sensing in undiluted serum with suspended microchannel resonators.
Improved methods are needed for routine, inexpensive monitoring of biomarkers that could facilitate earlier detection and characterization of cancer. Suspended microchannel resonators (SMRs) are highly sensitive, batch-fabricated microcantilevers with embedded microchannels that can directly quantify adsorbed mass via changes in resonant frequency. As in other label-free detection methods, biom...
متن کامل