Central corneal thickness measurement with different devices in keratoconic patients
نویسندگان
چکیده
We read with great interest the article by Aghazadeh Amiri et al. concerning the corneal thickness (CT) measurements with Scheimpflug and slit scanning imaging techniques in keratoconus (KC). We would like to congratulate with the authors for their very interesting paper because it is well known that the measurement of CT is involved in the reliability of intraocular pressure measurements, both in virgin eyes and in those that underwent photorefractive keratectomy (PRK), but it is also fundamental in deciding which technique can be more appropriate for the treatment of KC. The paper by Aghazadeh Amiri et al. showed that despite the strong correlation between CT measurement readings with Pentacam and Orbscan, the inter-device difference was statistically significant, mainly in more advanced cases of KC. According to the authors, this confirms the results of some previous studies suggesting that these two devices are noninterchangeable in cases of KC, although they are interchangeable in normal cases. In our opinion, this is partially true as a previous study found Pentacam measurements to be thicker than those obtained with Orbscan II. This overestimation decreases in corneas thicker than 560 mm. The reason for these differences is unclear, but the distinct methodologies in each device and use of a correction factor in Orbscan might induce this tendency. On the other hand, Pentacam is an optical method of CT measurement similar to that of Orbscan; it might also require correction of the raw data to match its data to those of ultrasonic pachymetry. To our knowledge, however, the manufacturer has not disclosed whether this kind of correction is performed in the machine. The study by Aghazadeh Amiri et al. found the evaluation of central CT to be different in all grades of KC, whereas the evaluation of the thinnest point is very similar in grade 1 KC
منابع مشابه
Central and Peripheral Corneal Thickness Measurement in Normal and Keratoconic Eyes Using Three Corneal Pachymeters
PURPOSE To assess the agreement among ultrasonic pachymetry, the Galilei dual Scheimpflug analyzer, and Orbscan II for central and peripheral (Galilei vs. Orbscan) corneal thickness (CCT and PCT) measurement in normal and keratoconic eyes. METHODS In this prospective study, CCT and PCT were measured in 88 eyes of 88 refractive surgery candidates and 128 eyes of 69 keratoconic patients with ul...
متن کاملIdentifying more reliable parameters for the detection of change during the follow-up of mild to moderate keratoconus patients
Background Reaching a consensus on which parameters are most reliable at detecting progressive keratoconus patients with serial topography imaging is not evident. The aim of the study was to isolate the parameters best positioned to detect keratoconus progression using the Pentacam HR® measures based on the respective limits of repeatability and range of measurement. Method Using the Pentacam...
متن کاملComparison of corneal measurements in keratoconic eyes using rotating Scheimpflug camera and scanning-slit topography.
AIM To compare the anterior segment measurements obtained by rotating Scheimpflug camera (Pentacam) and Scanning-slit topography (Orbscan IIz) in keratoconic eyes. METHODS A total of 121 patients, 71 males (58.7%) and 50 females (41.3%) (214 eyes) with the diagnosis of keratoconus (KC) were enrolled in this study. Following diagnosis of KC by slit-lamp biomicroscopic examination, central corn...
متن کاملComparison of Optical versus Ultrasonic Biometry in Keratoconic Eyes
Purpose. To compare the measurements of optical versus ultrasonic biometry devices in keratoconic eyes. Materials and Methods. Forty-two eyes of 42 keratoconus (KC) patients enrolled in the study were examined. Clinical and demographic characteristics of the patients were noted, and detailed ophthalmological examination was performed. Following Pentacam measurements, central corneal thickness (...
متن کاملComparison of Central Corneal Thickness Measured through Pentacam, OCTCasia2, and Orbscan IIz in Normal Individuals
Purpose: To compare the central corneal thickness measured through Pentacam, OCTCasia2, and Orbscan IIz in normal individuals. Methods: In this cross sectional comparative study, the researcher investigated the eyes of 70 normal candidates (140 eyes) with the mean age of 31.42 ± 7.70, referring to Dr. Sedaghat eye clinic for refractive surgery. For each person, Central Corneal Thickness (CCT) w...
متن کاملCorrelation between epithelial thickness in normal corneas, untreated ectatic corneas, and ectatic corneas previously treated with CXL; is overall epithelial thickness a very early ectasia prognostic factor?
PURPOSE To determine and correlate epithelial corneal thickness (pachymetric) measurements taken with a digital arc scanning very high frequency ultrasound biomicroscopy (HF UBM) imaging system (Artemis-II), and compare mean and central epithelial thickness among normal eyes, untreated keratoconic eyes, and keratoconic eyes previously treated with collagen crosslinking (CXL). METHODS Epitheli...