Contrast-enhanced ultrasound and real-time elastography in the differential diagnosis of malignant and benign thyroid nodules.

نویسندگان

  • Xin Sui
  • Huai-Jun Liu
  • Hong-Li Jia
  • Qin-Mao Fang
چکیده

The diagnostic value of contrast-enhanced ultrasound (CEUS) or real-time elastography (RTE) alone, as well as a combination of CEUS and RTE, in distinguishing benign from malignant thyroid nodules was investigated. Between August 2012 and June 2014, a total of 97 consecutive patients (50 male and 47 female patients; mean age, 48.6±12.4; age range, 27-70 years) with thyroid nodules referred for surgical treatment were examined by CEUS and RTE. The final diagnosis was obtained based on histological findings. Image analysis of the CEUS and RTE scans was performed. Considering the postoperative pathological results as the golden standard, a receiver operating characteristic (ROC) curve was constructed. Subsequently, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of CEUS alone, RTE alone and CEUS + RTE combination were calculated. Pathological examination showed 66 papillary carcinomas and 43 benign lesions, including 21 adenomas and 22 nodular goiters. The sensitivity, specificity, PPV, NPV and accuracy of CEUS were 81.82, 90.70, 93.10, 90.70 and 85.32%, respectively. In the case of RTE, the sensitivity, specificity, PPV, NPV and accuracy were 80.30, 88.37, 91.38, 88.37 and 83.49%, respectively. Furthermore, the combination of CEUS + RTE had a sensitivity of 95.45%, specificity of 95.35%, PPV of 96.92%, NPV of 95.35% and accuracy of 95.41%. Therefore, the CEUS + RTE combination showed a significantly higher sensitivity and specificity compared with CEUS or RTE alone (all P<0.05). Based on ROC analysis, the area under the curve (AUC) for CEUS, RTE and CEUS + RTE combination was 0.883, 0.863 and 0.959, respectively. The AUC of RTE alone was significantly lower compared with that of the CEUS + RTE combination. In conclusion, our results demonstrate that CEUS + RTE combination significantly increases the diagnostic performance for differential diagnosis of malignant and benign thyroid nodules compared with CEUS or RTE alone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Computerize classification of Benign and malignant thyroid nodules by ultrasound imaging

Introduction: Early detection and treatment of thyroid nodules increase the cure rate and provide optimal treatment. Ultrasound is the chosen imaging technique for assessment of thyroid nodules. Confirmation of the diagnosis usually demands repeated fine needle aspiration biopsy (FNAB). So, current management, has morbidity and non zero mortality. The goal of the present study ...

متن کامل

Real-time ultrasound elastography in the differential diagnosis of benign and malignant thyroid nodules.

OBJECTIVE The purpose of this study was to evaluate the diagnostic utility of real-time ultrasound elastography in differentiating benign from malignant thyroid nodules. METHODS A total of 90 consecutive patients with thyroid nodules who were referred for surgical treatment were examined in this prospective study. One hundred forty-five nodules in these patients were examined by B-mode ultras...

متن کامل

The differentiation of benign and malignant thyroid nodules.

The purpose of this study was to evaluate the predictive value of real-time ultrasound elastography (RUE) in differentiating benign from malignant thyroid nodules, with fine needle aspiration cytology analysis as the reference standard. A total of 78 consecutive patients with thyroid nodules who were selected for fine needle aspiration biopsies were examined in this prospective study. 78 nodule...

متن کامل

Application of Real-time Ultrasound Elastography in Diagnosing Benign and Malignant Thyroid Solid Nodules

OBJECTIVE Real-time ultrasound elastography (US-E) is a helpful tool in diagnosing thyroid nodules. This study aims to evaluate thyroid solid nodules, to establish the accuracy of US-E in providing information on the nature of these nodules, and to assess the clinical value of elasticity scores (ES) and strain ratio (SR) in differentiating thyroid solid nodules and to explore its distribution c...

متن کامل

Diagnostic value of strain ratio measurement in differential diagnosis of thyroid nodules coexisted with Hashimoto thyroiditis.

OBJECTIVE To evaluate the differential diagnostic potential of lesion stiffness assessed by the sonoelastographic strain index ratio (SR) for thyroid nodules coexist with Hashimoto thyroiditis (HT). METHODS A total of 50 focal thyroid nodules from 36 patients with HT (mean age 38.4 years; range 19-77) scheduled for fine-needle aspiration or thyroid surgery were included. After a routine conve...

متن کامل

Comparison of Conventional Ultrasound, Doppler, Elastography and Contrast Enhanced Ultrasonography Parameters with Histopathology Findings in the Differential Diagnosis of Benign and Malignant Thyroid Nodules

Background: Though neck ultrasound is the first line of choice for the screening of thyroid nodules, very few studies have compared the diagnostic performances of both conventional and advanced ultrasound parameters. In this study, we aim to compare various conventional and advanced ultrasound imaging parameters and confirm it with histopathology findings to differentiate between benign and mal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Experimental and therapeutic medicine

دوره 12 2  شماره 

صفحات  -

تاریخ انتشار 2016