Liposome retention in size exclusion chromatography

نویسندگان

  • Tristan Ruysschaert
  • Audrey Marque
  • Jean-Luc Duteyrat
  • Sylviane Lesieur
  • Mathias Winterhalter
  • Didier Fournier
چکیده

BACKGROUND Size exclusion chromatography is the method of choice for separating free from liposome-encapsulated molecules. However, if the column is not presaturated with lipids this type of chromatography causes a significant loss of lipid material. To date, the mechanism of lipid retention is poorly understood. It has been speculated that lipid binds to the column material or the entire liposome is entrapped inside the void. RESULTS Here we show that intact liposomes and their contents are retained in the exclusion gel. Retention depends on the pore size, the smaller the pores, the higher the retention. Retained liposomes are not tightly fixed to the beads and are slowly released from the gels upon direct or inverted eluent flow, long washing steps or column repacking. Further addition of free liposomes leads to the elution of part of the gel-trapped liposomes, showing that the retention is transitory. Trapping reversibility should be related to a mechanism of partitioning of the liposomes between the stationary phase, water-swelled polymeric gel, and the mobile aqueous phase. CONCLUSION Retention of liposomes by size exclusion gels is a dynamic and reversible process, which should be accounted for to control lipid loss and sample contamination during chromatography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Organic matter from biofilter nitrification by high performance size exclusion chromatography and fluorescence excitation-emission matrix

A combination of high performance size exclusion chromatography with organic carbon detector and ultraviolet detector coupled with peak-fitting technique and fluorescence excitation-emission matrix spectrometry applied fluorescence regional integration method was conducted to determine the characteristics of organic matter during nitrification. The batch scale of bionet nitrification without or...

متن کامل

Measurements of protein-protein interactions by size exclusion chromatography.

A method is presented for determining second virial coefficients (B(2)) of protein solutions from retention time measurements in size exclusion chromatography. We determine B(2) by analyzing the concentration dependence of the chromatographic partition coefficient. We show the ability of this method to track the evolution of B(2) from positive to negative values in lysozyme and bovine serum alb...

متن کامل

Interactions of drugs and an oligonucleotide with charged membranes analyzed by immobilized liposome chromatography.

We studied the effect of charged lipids or detergent on the retention of drugs and an oligonucleotide by immobilized liposome chromatography to characterize solute-membrane interactions. This is a novel approach in analysis of oligonucleotide-liposome interactions. The charged lipids (phosphatidylserine or distearoyltrimethylammoniumpropane) or detergent (sodium dodecylsulfate) interacted elect...

متن کامل

Liposome size analysis by dynamic/static light scattering upon size exclusion-/field flow-fractionation.

The aim of the current study was to analyse the particle size distribution of a liposome dispersion, which contained small egg phosphatidylcholine vesicles and had been prepared by high-pressure homogenisation, by various size analysis techniques. Such liposomes were chosen since they can be looked at as a prototype of drug nano-carriers. Three sub-micron particle size analysis techniques were ...

متن کامل

Critical conditions of polymer chromatography: an insight from SCFT modeling.

In polymer chromatography, chain molecules are separated by molecular weight, size, and chemical composition due to adsorption and exclusion in nanoporous substrates. Three regimes of separation are distinguished depending on the adsorption strength and the pore size. In the regime of size exclusion chromatography, the adsorption energy is weak and the separation is entropy-driven with larger m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC Biotechnology

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2005