Development of a balloon volume sensor for pulsating balloon catheters.
نویسندگان
چکیده
Helium pulsed balloons are integral components of several cardiovascular devices, including intraaortic balloon pumps (IABP) and a novel intravenous respiratory support catheter. Effective use of these devices clinically requires full inflation and deflation of the balloon, and improper operating conditions that lead to balloon under-inflation can potentially reduce respiratory or cardiac support provided to the patient. The goal of the present study was to extend basic spirographic techniques to develop a system to dynamically measure balloon volumes suitable for use in rapidly pulsating balloon catheters. The dynamic balloon volume sensor system (DBVSS) developed here used hot wire anemometry to measure helium flow in the drive line from console to catheter and integrated the flow to determine the volume delivered in each balloon pulsation. An important component of the DBVSS was an algorithm to automatically detect and adjust flow signals and measured balloon volumes in the presence of gas composition changes that arise from helium leaks occurring in these systems. The DBVSS was capable of measuring balloon volumes within 5-10% of actual balloon volumes over a broad range of operating conditions relevant to IABP and the respiratory support catheter. This includes variations in helium concentration from 70-100%, pulsation frequencies from 120-480 beats per minute, and simulated clinical conditions of reduced balloon filling caused by constricted vessels, increased driveline, or catheter resistance.
منابع مشابه
Response characteristics of esophageal balloon catheters handmade using latex and nonlatex materials
The measurement of esophageal pressure allows for the calculation of several important and clinically useful parameters of respiratory mechanics. Esophageal pressure is often measured with balloon-tipped catheters. These catheters may be handmade from natural latex condoms and polyethylene tubing. Given the potential of natural latex to cause allergic reaction, it is important to determine whet...
متن کاملO-32: Pain Experienced during Sonohysterography :Cervical to Uterine Catheter Placement
Background: The aim of this study is to evaluate whether the location of the balloon placement into either the cervical canal or uterine cavity during sonohysterography can affect the intensity of pain. Materials and Methods: A total of 300 infertile women undergoing sonohysterography were randomized to intracervical or intrauterine balloon placement. The examination was scheduled in the early ...
متن کاملPTA is an Outpatient Procedure
Dotter and Judkins in 1964, the Dotter set was a combination of 8 and 12 Fr coaxial Teflon catheters. Under these conditions, which involved the risk of severe afterbleeding, possible pulsating hematomas, av-fistulas and acute rethromboses in the groin arteries, it was more than reasonable to perform interventional radiological procedures instead of vascular surgery only under stationary condit...
متن کاملInvestigating the effects of random balloon pulsation on gas exchange in a respiratory assist catheter.
We are developing an intravenous respiratory assist catheter, which uses hollow-fiber membranes wrapped around a pulsating balloon that increases oxygenation and CO2 removal with increased balloon pulsation. Our current pulsation system operates with a constant rate of pulsation and delivered balloon volume. This study examined the hypothesis that random balloon pulsation would disrupt fluid en...
متن کاملAssessing respiratory function depends on mechanical characteristics of balloon catheters.
BACKGROUND Respiratory muscle function and lung and chest wall mechanics are reliably assessed by esophageal and gastric balloon catheters. The aim of this in vitro bench study was to assess the mechanical properties of commercially available balloon catheters using an experimental model with 3 defined compliances (27, 54, 90 mL/cm H2O). METHODS Six catheters were investigated in 4 conditions...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- ASAIO journal
دوره 50 3 شماره
صفحات -
تاریخ انتشار 2004