Diagnosis of venous incompetence in erectile dysfunction. Comparative study of cavernosography and Doppler ultrasound.
نویسندگان
چکیده
In 26 of 214 patients with erectile dysfunction and proved venous incompetence by cavernosography, an additional bidirectional Doppler ultrasound was performed also to demonstrate venous outflow disturbances. All except one leakage in the superficial and deep dorsal veins could be demonstrated as well as 4 of 6 cavernosum-glandular shunts. Bidirectional Doppler ultrasound visualized a continuous retrograde blood flow from the sulcus coronarius to the root of the penis in superficial and deep dorsal penile veins as well as in ectopic penile veins, an orthograde blood flow in the sulcus coronarius in cavernosum-glandular shunt.
منابع مشابه
شیوع نسبی علل نوار مغزی غیر طبیعی و برخی عوامل موثر در آن در مرکز نوروالکتروفیزیولوژی بیمارستان امام طی یک سال و نیم
Erectile dysfunction is an important problem for men and their families which has an organic cause in about 50 percent of cases. When there is a vasculogenic etiology for this defect, radiologic assessment is unavoidable. Cavernosometry and Cavernosography are ultimate procedures for diagnosis of venous leakage. There is no reliable data about this defects in Iran. The objective of this study w...
متن کاملبررسی فراوانی نشت وریدی در بیماران دچار اختلال نعوظی به وسیله فارماکوکاورنوزومتری و کاورنوزوگرافی در بیماران مراجعه کننده به بخش رادیولوژی بیمارستان سینا در سال 1378
Erectile dysfunction is an important problem for men and their families which has an organic cause in about 50 percent of cases. When there is a vasculogenic etiology for this defect, radiologic assessment is unavoidable. Cavernosometry and Cavernosography are ultimate procedures for diagnosis of venous leakage. There is no reliable data about this defects in Iran. The objective of this study w...
متن کاملبررسی آناتومی ورید پنیس با استفاده از سیتی کاورنوزوگرافی در مبتلایان به اختلال نعوظ با منشاء وریدی
Background: Erectile dysfunction is an important problem in men and an organic cause is found in about 50% of cases. When a vasculogenic etiology is suspected, imaging assessments are of great help. Cavernosography is traditionally recognized as an imaging modality for evaluation of venous leakage in men with impotency. We employed CT cavernosography as a novel technique for demonstrating penil...
متن کاملComprehensive assessment of cavernosography with 320-row dynamic volume CT versus conventional cavernosography in erectile dysfunction patients caused by venous leakage
The present study aims to investigate and compare the diagnostic and prognostic value of cavernosography with 320-row dynamic volume computed tomography (DVCT) versus conventional cavernosography in men with erectile dysfunction (ED) caused by venous leakage. A total of 174 patients diagnosed with ED were enrolled and received cavernosography with 320-row DVCT (DVCT group) and conventional cave...
متن کاملI-44: Color Doppler Imaging in Impotence
Sexual impotent is very common entity and define as inability to induce or maintaining penile erection during sexual intercourse. Studies reveals about 10% of men aged 40-70 years have complete, 17% have mild and 25% have moderate amount of erectile dysfunction. The sexual impotence has different etiology including psychogenic, neurogenic, arteriogenic and venogenic causes. Current studies reve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Urology
دوره 35 3 شماره
صفحات -
تاریخ انتشار 1990