Treatment of grade IIIB opens tibial fracture by Ilizarov hybrid external fixator.
نویسندگان
چکیده
OBJECTIVE We evaluated the results of patients who were treated with Ilizarov hybrid external fixator for type IIIB open tibial fractures. MATERIALS AND METHODS 35 Gustilo grade IIIB tibial fractures of age between 18 to 42 years (22 male and 13 female) in which 12 distal fourth tibia (D/4) of C1.1 (6), C1.3 (6), 12 upper fourth Tibia (U/4) of A2 (8) and A3 (4) according to AO classification and 11 Tibial plateau fractures of Schatzker type VI (5) , V(5), IV(1) . All tibial plateau, proximal fourth fractures and lower fourth fractures of tibia and fibula (Reversed Hybrid), treated with Ilizarov hybrid fixator using two Ilizarov 5/8 rings and AO External fixator were followed up to 12-52 months. RESULTS D/4 fractures were united at 31.16678.3046 wks, U/4 at 24.005.2915 and Tibial plateau at 15.5454.160 weeks (p-0.00). ROM in tibial plateau type IV 130 degrees +/- 00, type V 124 degrees +/- 8.94 degrees, type VI 125 degrees +/- 7.0711 degrees, D/4 of type C1.1 (50 degrees +/- 0.00), type C1.3 (43 degrees +/- 5.7755) whereas full ROM in U/4 fractures. Pin tract infection occurred in 21% of cases. Pain on walking in 20% of cases of type VI tibial plateau fractures and 80% of cases of type IV and V. Problem free in rest of parameter of function of VI and 100% problem in IV and V. Pain at rest observed in 20% of cases in type V. In 66.67% U/4 fractures had pain on walking but no other functions were compromised. In 33% D/4 fractures of C1.1 type had pain on walking only and had 1cm of shortening. CONCLUSION On the basis of our experience, we suggest adopting this method for functional limb salvage after extensive complex high-energy injuries. This fixator is safe and versatile, effective in providing stability and allowing early rehabilitation, although the indications for its use are very relatively specific.
منابع مشابه
Retrospective study of open tibial diaphyseal fractures type IIIA and IIIB by Ilizarov method
Background and objective: Open tibial fracture with or without bone loss in gustilo Anderson type IIIA and IIIB has been a challenge for most orthopaedic surgeons. Open tibial fracture is more prone for infection, non union and longer morbidity. In this study, we have evaluated the results of 34 patients with open tibial fracture GA type IIIA and IIIB by Ilizarov method in retrospective manner....
متن کاملIlizarov Versus AO External Fixator for the Treatment of Tibia Open Fractures
BACKGROUND In developing countries, Ilizarov or AO external fixator is usually used for treatment of tibial open fractures. The purpose of this study was to compare the efficacy of these two methods for treatment of tibial open fractures. METHODS From April 2002 to April 2010, 120 patients with open tibial fractures admitted to the Department of Orthopedics of Babol University of Medical Scie...
متن کاملTen year experience with use of Ilizarov bone transport for tibial defects.
Tibial defects greater than 4 cm and secondary to high-energy trauma or debridement for infected nonunion pose a significant challenge to the treating orthopaedic surgeon. Twelve patients who had been treated with Ilizarov bone transport for tibial defects over the past ten years were retrospectively reviewed. All patients were male with an average age of thirty-two. Ten of the twelve limbs wer...
متن کاملModified hybrid fixator for high-energy Schatzker V and VI tibial plateau fractures
High-energy tibial plateau fractures associated with severe soft tissue injury are difficult to manage. The risk of wound complications following open reduction and internal fixation is notably high owing to extensive soft tissue dissection. Alternatively, application of hybrid external fixator minimizes soft tissue dissection and provides adequate fracture stabilization to allow early range of...
متن کاملIntra-articular fractures of the tibial plafond. A comparison of the results using articulated and ring external fixators.
We retrospectively reviewed 60 fractures of the tibial plafond treated by either an ankle-sparing diaphyseal-epiphyseal technique using the Ilizarov ring fixator or by an ankle-spanning technique using a monolateral articulated external fixator. The Ilizarov ring fixator was applied in 24 fractures and the monolateral articulated transarticular external fixator in 20. Both techniques were combi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Kathmandu University medical journal
دوره 5 2 شماره
صفحات -
تاریخ انتشار 2007