Evaluation of the PotoClean® decontamination technology for reprocessing of water supply lines in dental units during routine work

نویسندگان

  • Axel Kramer
  • Torsten Koburger
  • Lisa-Dorothea Taube
  • Michael Menzel
  • Georg Meyer
  • Ojan Assadian
چکیده

BACKGROUND A frequent problem in dental units is the microbial contamination of water and biofilm formation in the water supply lines. After random identification of a bacterial contaminated dental unit (310 cfu/ml) in a practise with 3 dental units we implemented the present study to evaluate the efficacy of the PotoClean(®) technology, based on anodic oxidation. METHOD The efficacy of a regular low concentrated permanent decontamination (1 mg Cl/L) with an additional intensive decontamination by PotoClean(®) (three times 20 mg Cl/ml for 2 h) on three dental units was tested over 7 months. Microbial contamination, total chlorine concentration and redox potential have been analyzed. Dental unit A and B was 15 years old, unit C 5 years. RESULTS After 3 intensive decontaminations, in dental unit A and B the number of bacteria and moulds could be reduced less than 7 d. Thereafter the bacteria counts increased again during the subsequent 7 month period and the amount of moulds was with some exceptions 300 cfu/ml, although PotoClean(®) was constantly added in the system (1 mg Cl/L). After further 7.5 month only with low concentrated permanent disinfection (1 mg Cl/L) both units were successful decontaminated. Dental unit C represented an object which was easier to decontaminate because of the advanced construction (prevention of water stagnation) and the shorter useful life. At the beginning of the decontamination it was no bacterial contamination, but moulds were contained (300 cfu/ml). Already after the first intensive decontamination, no further bacteria and moulds could be detected. DISCUSSION An important factor for the efficacy of PotoClean(®) was the age of the units and their construction. For a new generation of dental units PotoClean(®) was effective during the whole period of monitoring. For two old types of dental unit with massive biofilm development the successful decontamination needed more than 7 month. CONCLUSION The PotoClean(®) technology has resulted in even old-type turbines with intensive biofilm formation to complete decontamination. In a recent turbine design already after the first intensive decontamination with PotoClean(®) and its continuous use (1 mg Cl/L) no more contamination by bacteria and moulds were detectable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating Bacterial Contamination of Water Supply in Dental Units at Alborz University of Medical Science Using Microbial Culture and Colony Count in 2019

Introduction: With respect to the outbreak probability of dangerous infections among the patients, the water sources of dentistry units were taken into consideration, in view of microbial contamination. The objective of this study was to assess of pathogenic organisms of the water used in the dentistry units at Alborz Dental School. Material and methods: In this study, 120 samples from high spe...

متن کامل

Evaluation of Bacterial Contamination in Dental Unit Water Lines in Zahedan in 2016-2017

Background & Aim: Due to a constant contact of dentists and patients with water and aerosols generated from the dental units, the quality of dental unit waters is very important. This study aimed to evaluate bacterial contamination of dental unit water lines in Zahedan in 2016-2017. Methods: In this descriptive analytical study, 2304 water samples from four parts of unit including cup filler, ...

متن کامل

A Study on Microbial Quality of Water Supply in Dental Units at Bojnourd Dental School in 2017

Introduction: Dental units are among the equipment that flows through the dental application, and due to the durability of water and the probability of forming the biofilm. They can have a high microbial load. It is important to investigate this pollution, which should be frequently investigated due to the incidence of dangerous infections in people with weakness of the defense system, pollutio...

متن کامل

Performance Evaluation of Point-Of-Use Drinking Water Treatment Units in Removal of Heavy Metals and Dissolved Solids from Drinking Water Supply in Tabriz

Introduction: Application of point-of-use (POU) drinking water treatment units is expanding across the world due to the increased concerns about the adverse health effects of water pollution. The main treatment systems of these devices are mostly activated carbon and nano-filter or reverse osmosis. Materials and Methods: This study was conducted to evaluate the effect of using POU units on phy...

متن کامل

Impact of Capacity of Mobile Units on Blood Supply Chain Performance: Results from a Robust Analysis

Background and Objectives: A sudden jump in blood demand during natural disasters may have strong negative impact on the performance of blood supply chain. Appropriate response to emergency situations requires predictive approach to determining the optimal allocation of blood supply chain resources for various disaster scenarios. The present study, thus, presents an optimization model aimed at ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012