Tracheobronchomegaly: a rare cause of endotracheal tube cuff leak.

نویسندگان

  • Joshua B Ng
  • Edward A Bittner
چکیده

A 63-yr-old man (height, 173 cm) with a remote history of bronchiectasis and a double lung transplant was emergently intubated during a recent bout of bronchitis. An air leak was noted with positive-pressure ventilation through an 8.0-mm cuffed endotracheal tube until the cuff contained 12 ml air, with a cuff pressure of 22 cm H2O. This computed tomographic image shows the following: (A) the endotracheal tube in situ and (B) the cuff’s location. The tracheal diameter below the tube (C) measured 31.5 mm; this caused the cuff leak. A medical record review revealed minor tracheobronchial dilatation before transplantation. This patient experienced Mounier-Kuhn syndrome, a rare condition first described in 1932. The syndrome is characterized by tracheobronchomegaly and is associated with tracheal diverticulosis and bronchiectasis. Patients present with recurrent pulmonary infections usually by the third or fourth decade of life. Although approximately 100 cases have been documented, the presentation is nonspecific and the condition may be missed on a plain radiograph; therefore, the true incidence is likely higher. Tracheobronchomegaly is likely the result of atrophy of smooth muscle and elastic connective tissue in the conducting airways. The diagnosis is made radiologically when the diameter of the trachea, right main bronchus, or left main bronchus exceeds 30, 24, or 23 mm, respectively. Treatment is generally supportive and may include chest physiotherapy, antibiotics, tracheal stenting, and, rarely, pulmonary transplantation. During general anesthesia, patients with tracheobronchomegaly are at risk of large airway collapse and obstruction, aspiration pneumonitis, and tracheal trauma after airway instrumentation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mounier-Kuhn Syndrome: Anesthetic Experience

Mounier Kuhn syndrome, or congenital tracheobronchomegaly, is an under diagnosed clinical entity with peculiar anatomical and physiological features making anesthetic care challenging. A 58-year-old chronic smoker with history of recurrent pneumonia and bronchiectasis presented for septoplasty. Thoracic imaging revealed a dilated trachea and main bronchi, tracheal and bronchial diverticuli, and...

متن کامل

Repeated Tracheostomy Tube Cuff Rupture Due to Tracheobronchopathia Osteochondroplastica: A Case Report

Introduction: Tracheobronchopathia osteochondroplastica (TPO) is a rare benign disorder of the lower part of the trachea and the upper part of the main bronchi.   Case Report: A case of tracheobronchopathia osteochondroplastica (TPO) diagnosed at the time of intubation in an intensive care unit due to difficulty when advancing the endotracheal tube beyond the vocal cords, is reported. A problem...

متن کامل

Needle Perforation of an Endotracheal Tube Cuff Pilot Line

A surgical needle will generally not penetrate an endotracheal tube (ETT) and intraoperative ETT cuff perforation is uncommon because the cuff, which is the weakest part of the tube, is placed in the subglottic trachea. We report a very rare case, in which an intraoperative airway air leak during maxillary advancement surgery was postoperatively confirmed to be due to ETT cuff deflation because...

متن کامل

Comparison of tracheal tube cuff inflation pressure among anesthesia team with different gradual level

Background & Objectives: Tracheal intubation is frequently performed in operating room. Over inflation of the endotracheal tube cuff is a risk factor for tracheal ischemia and subsequent complications. On the other hand inadequate cuff pressure increases the risk of aspiration of gastric contents. In this study, the endotracheal tube cuff pressure filled by the anesthesia team has been compared...

متن کامل

Optimization of endotracheal tube cuff filling by continuous upper airway carbon dioxide monitoring.

UNLABELLED Inappropriate cuff filling is responsible for various complications related to the use of an endotracheal tube (ETT). In this study, we evaluated an objective, noninvasive method for continuous assessment of leak around the ETT cuff by monitoring carbon dioxide pressure (P(CO2) in the upper airway. P(CO2) levels were measured by capnography simultaneously between the ETT cuff and the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 114 5  شماره 

صفحات  -

تاریخ انتشار 2011